arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.
By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
arXiv:2610.28507v1 Announce Type: cross
Abstract: Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG r...
By Walentin Palanchuk
arXiv:2608. 03690v1 Announce Type: new Abstract: Point-of-care cardiac devices such as smartwatches and handheld ECG recorders typically capture 1--2 leads, yet existing ECG foundation models are architecturally constrained to fixed 12-lead inputs, degrading or failing under these reduced configurations.
By Edoardo Coppola, Stefano Fiorini, Pietro Li\`o, Mattia Savardi, Alberto Signoroni
arXiv:2608. 14633v1 Announce Type: cross Abstract: Wolff-Parkinson-White (WPW) syndrome is a congenital cardiac pre-excitation, clinically important and often missed on the resting 12-lead ECG.
By Nathael Altman
The paper introduces GRAFT-EEG, a method that removes the active‑set common‑reference gauge and transports each native EEG mask through a template motor leadfield, enabling target‑statistics‑blind transfer for cross‑dataset motor‑imagery decoding. Using a source‑fitted spectral classifier and a bounded state‑space‑model residual, the approach achieves higher balanced accuracy (60.865%) than a strict‑clean baseline (52.684%) across five leave‑one‑dataset‑out targets, and outperforms several control conditions in post‑hoc tests. The study also reports positive results in a separate 60‑participant same‑paradigm evaluation, though the dynamic‑static comparison was inconclusive.
"whyItMatters":"The method demonstrates that accounting for observation‑operator changes can substantially improve cross‑dataset EEG decoding performance, offering a more robust approach for motor‑imagery applications."
By Ying Zhou, Mengting Liu
The study investigates how patient‑adaptive ECG lead‑channel allocation policies perform when evaluated by different diagnostic models. Two policies, ECG‑on‑Demand and MGA, trained with a simple logistic evaluator were tested on a more powerful ResNet1D evaluator, revealing that the adaptive advantage observed with the training evaluator disappears or reverses with the stronger evaluator. Across multiple budgets, policies, and metrics, all interactions favor fixed protocols under the strong evaluator, suggesting that adaptive channel selection must be jointly optimized with the diagnostic backbone.
By Xiaoyang Li, Zeyan Tao