arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.
By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
arXiv:2610.28507v1 Announce Type: cross
Abstract: Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG r...
By Walentin Palanchuk
arXiv:2608. 03690v1 Announce Type: new Abstract: Point-of-care cardiac devices such as smartwatches and handheld ECG recorders typically capture 1--2 leads, yet existing ECG foundation models are architecturally constrained to fixed 12-lead inputs, degrading or failing under these reduced configurations.
By Edoardo Coppola, Stefano Fiorini, Pietro Li\`o, Mattia Savardi, Alberto Signoroni
arXiv:2608. 14633v1 Announce Type: cross Abstract: Wolff-Parkinson-White (WPW) syndrome is a congenital cardiac pre-excitation, clinically important and often missed on the resting 12-lead ECG.
By Nathael Altman
The paper introduces GRAFT-EEG, a method that removes the active‑set common‑reference gauge and transports each native EEG mask through a template motor leadfield, enabling target‑statistics‑blind transfer for cross‑dataset motor‑imagery decoding. Using a source‑fitted spectral classifier and a bounded state‑space‑model residual, the approach achieves higher balanced accuracy (60.865%) than a strict‑clean baseline (52.684%) across five leave‑one‑dataset‑out targets, and outperforms several control conditions in post‑hoc tests. The study also reports positive results in a separate 60‑participant same‑paradigm evaluation, though the dynamic‑static comparison was inconclusive.
"whyItMatters":"The method demonstrates that accounting for observation‑operator changes can substantially improve cross‑dataset EEG decoding performance, offering a more robust approach for motor‑imagery applications."
By Ying Zhou, Mengting Liu
The study investigates how patient‑adaptive ECG lead‑channel allocation policies perform when evaluated by different diagnostic models. Two policies, ECG‑on‑Demand and MGA, trained with a simple logistic evaluator were tested on a more powerful ResNet1D evaluator, revealing that the adaptive advantage observed with the training evaluator disappears or reverses with the stronger evaluator. Across multiple budgets, policies, and metrics, all interactions favor fixed protocols under the strong evaluator, suggesting that adaptive channel selection must be jointly optimized with the diagnostic backbone.
By Xiaoyang Li, Zeyan Tao
The paper introduces Normal-Anchored Geometric Transport (NAGT), a source‑free adaptation technique that uses label‑free normal beats from the first five minutes of ECG recordings to compute a symmetric positive‑definite congruence map. NAGT applies this map only to normal and supraventricular prototypes while keeping ventricular and fusion prototypes unchanged, achieving a macro‑F1 improvement from 34.5% to 48.7% on a large chest‑patch cohort. The method also reduces ventricular false alarms by 68% and maintains 98.3% of normal beats outside alarm classes, with adaptation taking only 5.8 ms per record.
By JinKook Kim
arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.
By Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana, Pradyot Tiwari, Subramani Kandasamy, KVS Hari
The paper introduces a deterministic encoding that compresses a twelve‑lead electrocardiogram into text suitable for large language models, balancing token count with information loss. Eight independent leads are encoded as amplitude letters and exact time gaps, while the remaining four limb leads are recovered algebraically. Applied to 21,388 PTB‑XL records, the method achieved an average token count of 2,866 (64.3% fewer than per‑sample transcription) with a decoded‑to‑reference signal correlation of 0.982 and negligible loss in diagnostic performance (AUC difference –0.0010).
By Elif Dorukba\c{s}{\i}, \.Ilker T\"urker
The paper introduces three sanity checks to evaluate whether architectural changes to Transformers—specifically removing components of attention heads—are justified by meaningful statistics in internal representations. Applying these checks to self‑attention removal across nine pretrained models, the authors find that a significant portion of head‑value cosine alignment is explained by a causal null, that alignment varies with key‑value grouping, and that the effect of removing the own‑value direction improves validation loss in large models but not in smaller ones. The study demonstrates that large cosine alignment alone does not guarantee redundancy, and that the benefit of removing a specific direction depends on model size and architecture.
By Basavaraj R M, Aryan Bharat Kumar
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
The study evaluates explainable AI methods for Remote Photoplethysmography (rPPG) using the RhythmFormer model across two datasets (NCKU-rPPG and UBFC-rPPG). Quantitative metrics—skin coverage and the Salience-guided Faithfulness Coefficient (SaCo)—were applied to four explanation techniques (raw attention, rollout, attention flow, and Beyond Intuition). Beyond Intuition consistently achieved the highest coverage and SaCo, while other methods showed weak or opposite correlations with performance measures, and performance degraded notably under low illumination (40 lux).
By Louis Chen, Torbj\"orn E. M. Nordling