The paper introduces AGW-PBR, a brain MRI super‑resolution method that emphasizes tissue‑transition regions affected by the partial‑volume effect. It uses a low‑resolution backbone guided by Sobel edges, soft latent‑basis assignment, and grid‑anchored warping, while training‑time weights are derived from tissue‑mixture entropy computed from registered T1/T2/PD images. Experiments on IXI T2‑weighted scans at 2×, 4×, and 6× show improved full‑image reconstruction and regional fidelity, and the backbone also performs well on fastMRI data without PVE supervision.
By Xiao Tong, Wenyun Yang, Ziheng Zhang, Jingzhi Han, Zhaochu Luo, Jinbo Yang
SliceBridge is a new framework for repairing corrupted slice intervals in T1‑weighted MRI by using rectified flow matching conditioned on surrounding intact slices and their relative positions. It enforces through‑plane consistency by coupling slices within the interval through shared noise, flow time, and synchronized sampling, then reinserts the restored interval without altering other slices. In experiments on 9,877 brain MRIs and 581 external subjects, SliceBridge reduced slice‑to‑slice error by 32.9%–41.3% and improved SSIM across interval lengths, while lowering downstream segmentation volume estimation error from 1.95% to 1.05%.
By Jiheng Li, Michael E. Kim, Trent Schwartz, Gaurav Rudravaram, Derek B. Archer, Timothy J. Hohman, the Alzheimer's Disease Neuroimaging Initiative, Lianrui Zuo, Bennett A. Landman
arXiv:2609.39083v1 Announce Type: new
Abstract: Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve d...
By Kavitha Viswanathan, Harsh Choudhary, Amit Sethi
arXiv:2605.24625v2 Announce Type: replace
Abstract: Ultra-low-field (ULF) MRI offers portable and accessible neuroimaging but suffers from reduced signal-to-noise ratio and limited spatial resolution...
By Toufiq Musah, Salvatore Calcagno, Federica Proietto Salanitri, Xiaomeng Li, Maruf Adewole, Marawan Elbatel
The paper introduces MR‑DiffuSR, a 3‑D latent diffusion framework that uses high‑resolution T1w structural priors to guide super‑resolution of thick‑slice FLAIR MRI scans. By applying cross‑modality structural swin attention and a mixed‑scale degradation strategy, the method avoids hallucinations and remains robust across varying slice thicknesses. On ADNI datasets, MR‑DiffuSR outperforms CNN and 2‑D diffusion baselines, achieving high PSNR, SSIM, and low LPIPS, and maintains strong white‑matter hyperintensity segmentation performance even at 7 mm equivalent slice thickness.
By Haoyu Lan, Jiazhen Zhang, John Onofrey, Bino Varghese, Nasim Sheikh-Bahaei, Arthur W. Toga, Jeiran Choupan
arXiv:2609.36837v1 Announce Type: cross
Abstract: Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and...
By Prathamesh Pradeep Khole, Shreya Handa, Utkarsh Gupta, Razvan Marinescu
arXiv:2607. 19137v1 Announce Type: cross Abstract: Inferring contrast enhancement from one pre-contrast breast MRI slice is underdetermined: post-contrast appearance contains physiological information that is not uniquely encoded in baseline anatomy.
By Andrea Borghesi, Xin Wang, Jonas Teuwen, George Yiasemis
arXiv:2609.00593v1 Announce Type: new
Abstract: Neuroradiologists rarely read a brain MRI in isolation, yet automated brain-MRI report generation has been built almost entirely for single studies. Te...
By Krish Patel, Peirong Liu
arXiv:2606. 00146v1 Announce Type: cross Abstract: Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability.
By Honglin Xiong, Yuxian Tang, Feng Li, Yulin Wang, Lei Xiang, Dinggang Shen, Qian Wang
arXiv:2608.28773v1 Announce Type: cross
Abstract: Perceptual losses are widely used in medical image synthesis because they encourage agreement in high-level structure beyond voxel-wise intensity sim...
By Changsheng Fang, Dayang Wang, T. Campbell Arnold, Enhao Gong, Srivathsa Pasumarthi
arXiv:2609.15888v1 Announce Type: cross
Abstract: Deep networks trained on structural MRI for Alzheimer's disease (AD) staging often reach reasonable accuracy while attending to anatomically irreleva...
By Paul-Gabriel Nicolae, Irina Georgiana Mocanu
The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya