arXiv:2601. 15235v4 Announce Type: replace-cross Abstract: Cervical spine fractures require rapid and accurate diagnosis, yet automatic CT interpretation remains challenging as subtle injuries must be assessed across large 3D volumes.
By Fabi Nahian Madhurja, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi, Sohaib Bassam Zoghoul
arXiv:2608.29348v1 Announce Type: new
Abstract: Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but...
By Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To, M\'at\'e Sik, C\'edric H\'emon, Thomas Weikert, Martin Segeroth
arXiv:2609.25743v1 Announce Type: new
Abstract: Interactive segmentation of 3D medical images supports quantitative analysis of anatomical structures and disease while allowing users to specify and r...
By Ping Gong, Shiyuan Su, Fandong Zhang, Xinchen Han, Haowei Sun, Yiming Li, Yizhou Yu
arXiv:2610.34529v1 Announce Type: cross
Abstract: Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learnin...
By Tansel Uyar
arXiv:2607. 10551v1 Announce Type: cross Abstract: Accurate geometric calibration is essential for fluoroscopy-guided spinal imaging, digitally reconstructed radiograph (DRR) generation, and 2D--3D vertebral registration.
By Lin Li, Chaochao Zhou, Benjamin Aubert, Junlin Guo, Junchao Zhu
SpineContextResUNet is a lightweight 3D Residual U‑Net that uses a Context Block with parallel multi‑dilated convolutions to efficiently capture long‑range anatomical dependencies for spine CT segmentation. It achieves Dice scores of 88.17% on VerSe2020 and 88.13% on CTSpine1K while maintaining a small ~1.7 M parameter footprint. Compared to resource‑heavy Transformers and baselines that fail on commodity hardware, SpineContextResUNet delivers robust inference on edge devices such as the Nvidia Jetson Orin Nano.
By K S Nithurshen, Saurabh J. Shigwan
arXiv:2603. 12514v2 Announce Type: replace-cross Abstract: Accurate detection and localization of traumatic injuries in abdominal CT remain challenging because voxel-level annotations are limited and expensive to obtain.
By Shivam Chaudhary, Sheethal Bhat, Andreas Maier
DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.
By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner
arXiv:2604.27697v2 Announce Type: replace-cross
Abstract: Peritoneal metastases (PM) are staged using the surgically determined Peritoneal Cancer Index (sPCI), which requires invasive laparoscopic as...
By Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Lenah D. Kampmeijer, Anna F. van Herwijnen, Marion W. Tops-Welten, Cris H. B. Claessens, Joost Nederend, Ignace H. J. T. De Hingh, Max J. Lahaye, Misha D. P. Luyer, Fons van der Sommen
The paper presents a clinically viable pipeline that uses routine intraoperative C‑arm fluoroscopy to derive per‑vertebra 6‑DoF poses, which are co‑registered to an RGB‑D camera via a multimodal fiducial array. This approach provides independent subsurface ground truth for validating markerless spinal tracking methods without adding radiation or altering standard surgical workflows. Ex vivo tests show an end‑to‑end accuracy of about 2 mm and 3.3°, and the framework is applied to evaluate two markerless registration strategies on real surgical data.
By Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
arXiv:2609.37648v1 Announce Type: new
Abstract: Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dime...
By Binghong Qian, Xuanhe Liu, Yifan Xing, Wenjie Deng, Jian Wu, Haochao Ying
The study presents a three‑stage framework for generating CT images from spinal MRI scans. First, an anatomy‑guided vertebral matching system creates pseudo‑paired data by aligning similar sagittal MRI and CT slices. Second, an adversarial diffusion model is trained on these pairs to translate MRI to CT, and third, a 3D refinement network stitches the synthesized slices into coherent volumes. The method, trained on over 10,000 unpaired slices and evaluated on 1,911 slices from 83 patients, improves vertebral Dice scores from 0.666 to 0.739 and reduces discontinuities between stacked slices.
By Eduardo Nieto, Ibai Genua, Davide Scorza, Karen L\'opez-Linares