arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
arXiv:2609.10376v1 Announce Type: new
Abstract: Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is...
By Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Fr\'ed\'eric Lavoie, Herve Lombaert
The paper introduces LiftXR, a geometry‑guided framework that first reconstructs a 3D anatomical layout from bi‑planar X‑ray images and then uses this layout to guide CT volume reconstruction. An anatomical parser refines the layout by analyzing the reconstructed CT, enabling region‑specific intensity calibration. Experiments on two public datasets show LiftXR surpasses recent X‑ray‑to‑CT methods and improves downstream segmentation performance.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatt...
arXiv:2609.24937v1 Announce Type: new
Abstract: Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this chall...
By Mrunmay Angaitkar, Piyush Kumar, Aarjav Satia, Pranav Rao, Ashish Mittal, Manoj Tadepalli, Preetham Putha
Generating a 3D dental volume from a single panoramic radiograph (PXR) could provide a low-radiation alternative to Cone-Beam Computed Tomography (CBCT), but the problem is highly underdetermined: panoramic acquisition integrates 3D attenuation along curved X-ray paths into a 2D image, leaving depth-resolved anatomy unobserved. Existing implicit and generative approaches often produce oversmoothed geometry or anatomically inconsistent hallucinations, lacking geometry-driven supervision and relying on smooth representations unable to precisely localize sharp anatomical boundaries.
ConRef is a multi‑view framework that audits reference poses in 2D/3D registration benchmarks by jointly analyzing multiple X‑ray observations to estimate an additional reference pose, quantify its uncertainty, and detect outliers. In validation on a bead‑based phantom dataset, ConRef’s estimates differed from independent references by only 0.08–0.12 mm, whereas discrepancies with the original references reached 2.06 mm on a femur dataset. The method also flagged 22 DeepFluoro X‑rays as potential outliers and showed that reference choice could alter sub‑millimeter success conclusions for the same registrations.
By Jianfeng Yue, Feng Li, Tianyu Song, Julius Watrinet, Ulrich Eck, Nassir Navab
Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this challenge with a digitally reconstructed radiograph (D...
The study presents a three‑stage framework for generating CT images from spinal MRI scans. First, an anatomy‑guided vertebral matching system creates pseudo‑paired data by aligning similar sagittal MRI and CT slices. Second, an adversarial diffusion model is trained on these pairs to translate MRI to CT, and third, a 3D refinement network stitches the synthesized slices into coherent volumes. The method, trained on over 10,000 unpaired slices and evaluated on 1,911 slices from 83 patients, improves vertebral Dice scores from 0.666 to 0.739 and reduces discontinuities between stacked slices.
By Eduardo Nieto, Ibai Genua, Davide Scorza, Karen L\'opez-Linares
arXiv:2609.26756v1 Announce Type: new
Abstract: X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray col...
By Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
XGLASS is a method that transfers expertise from 2D X‑ray vision‑language models to 3D CT volumes by using disease‑conditioned importance maps derived from radiologist gaze on X‑rays. By aligning these gaze priors with coronal CT projections, XGLASS predicts a disease‑specific ordering of axial slices, prioritizing diagnostically relevant slices. The approach achieves a top‑10 hit rate of up to 75.9% on a 240‑slice scan and reduces downstream model calls by 87.5% while improving F1 scores, making it a lightweight preselector for volumetric CT analysis.
By Michael Gl\"ockler, Timo Ropinski
Measuring the angle between bone structures is a routine task in medical image analysis and provides a key quantitative parameter for diagnosis and treatment planning. Automated methods can reduce time and cost while improving reproducibility.