arXiv:2610.24858v2 Announce Type: replace
Abstract: Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorte...
By Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus, Fabian Bamberg, Klaus Maier-Hein, Kai Schlamp, Alexander Radbruch, Gianluca Brugnara, Philipp Vollmuth
The study presents a three‑stage framework for generating CT images from spinal MRI scans. First, an anatomy‑guided vertebral matching system creates pseudo‑paired data by aligning similar sagittal MRI and CT slices. Second, an adversarial diffusion model is trained on these pairs to translate MRI to CT, and third, a 3D refinement network stitches the synthesized slices into coherent volumes. The method, trained on over 10,000 unpaired slices and evaluated on 1,911 slices from 83 patients, improves vertebral Dice scores from 0.666 to 0.739 and reduces discontinuities between stacked slices.
By Eduardo Nieto, Ibai Genua, Davide Scorza, Karen L\'opez-Linares
H-2DGS introduces a height-field 2D Gaussian Splatting pipeline that produces a sharp, deformable cortical surface reconstruction for neurosurgical navigation. The method concentrates a robust 3D Gaussian Splatting reconstruction, fuses its depth into a shared truncated signed distance field, and represents the surface with curved, surface-oriented Gaussian primitives. Across five real neurosurgical cases, H-2DGS achieves low multi-view depth inconsistency, a compact 7.97 MB representation, and interactive rendering at 29–42 ms per frame, integrating clearly with tractography and MRI anatomy.
By Zhang Zichuan, Bart Brouwers, Rembrandt Bakker, Maud Landers, Geert-Jan Rutten, Maxime Chamberland
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv:2609.10376v1 Announce Type: new
Abstract: Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is...
By Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Fr\'ed\'eric Lavoie, Herve Lombaert
The paper presents an anatomy‑aligned surface learning framework for reconstructing patient‑specific 4D myocardial surfaces from sparsely sampled short‑axis cine MRI. By parameterizing epicardial and endocardial surfaces on a shared circumferential‑longitudinal UV domain, the method transforms irregular 3D reconstruction into structured coordinate‑field completion, enabling explicit correspondence across subjects and cardiac phases. Experiments on three public datasets show the approach outperforms mesh‑based and implicit methods, achieving Chamfer distances around 2.6–2.9 mm and preserving ventricular function with small errors in volume and ejection fraction.
By Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li