arXiv Computer Vision By Robin Y. Park, Mark C. Eid, Rhydian Windsor, Amir Jamaludin, Ana I. L. Namburete, Jo\~ao F. Henriques, Andrew Zisserman

Rendering Novel Views of MRI Using 3D Gaussian Splatting

Read the original on arXiv Computer Vision →

The paper proposes using 3D Gaussian Splatting to reconstruct volumetric MRI data from non‑aligned scans, enabling the generation of novel view planes that are better aligned with spinal anatomy. These resampled images are then used to predict ordinal severity grades of localized stenosis, outperforming traditional Voxel Interpolation and Cubic B‑spline resampling methods. Across all stenosis conditions, the Gaussian Splatting approach yields more accurate diagnostic gradings than raw or conventionally resampled scans.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv Computer Vision.

arXiv Computer Vision
Oct 22

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

arXiv:2610.24858v2 Announce Type: replace Abstract: Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorte...

By Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus, Fabian Bamberg, Klaus Maier-Hein, Kai Schlamp, Alexander Radbruch, Gianluca Brugnara, Philipp Vollmuth
arXiv AI
Oct 28

MRI-to-CT Translation of Spinal Images via Anatomy-Guided Pseudo-Pairing and Adversarial Diffusion

The study presents a three‑stage framework for generating CT images from spinal MRI scans. First, an anatomy‑guided vertebral matching system creates pseudo‑paired data by aligning similar sagittal MRI and CT slices. Second, an adversarial diffusion model is trained on these pairs to translate MRI to CT, and third, a 3D refinement network stitches the synthesized slices into coherent volumes. The method, trained on over 10,000 unpaired slices and evaluated on 1,911 slices from 83 patients, improves vertebral Dice scores from 0.666 to 0.739 and reduces discontinuities between stacked slices.

By Eduardo Nieto, Ibai Genua, Davide Scorza, Karen L\'opez-Linares
arXiv Computer Vision
Oct 23

H-2DGS: Height-Field Gaussian Splatting for Sharp and Deformable Neurosurgical Surface Reconstruction

H-2DGS introduces a height-field 2D Gaussian Splatting pipeline that produces a sharp, deformable cortical surface reconstruction for neurosurgical navigation. The method concentrates a robust 3D Gaussian Splatting reconstruction, fuses its depth into a shared truncated signed distance field, and represents the surface with curved, surface-oriented Gaussian primitives. Across five real neurosurgical cases, H-2DGS achieves low multi-view depth inconsistency, a compact 7.97 MB representation, and interactive rendering at 29–42 ms per frame, integrating clearly with tractography and MRI anatomy.

By Zhang Zichuan, Bart Brouwers, Rembrandt Bakker, Maud Landers, Geert-Jan Rutten, Maxime Chamberland
arXiv AI
Jun 10

Deep Slice Interpolation for Reducing Through-Plane Anisotropy and Noise in Head CT

arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.

By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv Computer Vision
Sep 25

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

The paper presents an anatomy‑aligned surface learning framework for reconstructing patient‑specific 4D myocardial surfaces from sparsely sampled short‑axis cine MRI. By parameterizing epicardial and endocardial surfaces on a shared circumferential‑longitudinal UV domain, the method transforms irregular 3D reconstruction into structured coordinate‑field completion, enabling explicit correspondence across subjects and cardiac phases. Experiments on three public datasets show the approach outperforms mesh‑based and implicit methods, achieving Chamfer distances around 2.6–2.9 mm and preserving ventricular function with small errors in volume and ejection fraction.

By Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li