Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis...
Local2Mesh is a spatially localized contour‑to‑mesh framework that reconstructs 3‑D left ventricular geometry from sparse 2‑D cardiac MRI contours without requiring 3‑D mesh annotations. It corrects inter‑slice misalignment through geometry‑aware alignment and routes contour features to template vertices via a plane‑aware Local Router, then jointly uses local and global features to deform a template mesh. Experiments on M&Ms‑2 and ACDC datasets show superior geometric reconstruction, functional estimation, and disease classification compared to existing methods, with strong cross‑dataset generalization.
By Haoyu Wu, Ling Lin, Pascal Lef\`evre, Ruizhe Li, Xiaowu Sun
X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learnin...
arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
arXiv:2606. 13188v1 Announce Type: cross Abstract: Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating.
By Abhishek H S, Akash Ganamukhi, Abhimanyu Suresh, Aditya G Hiremath, Prasad B Honnavalli, Adithya Balasubramanyam
arXiv:2607. 02564v1 Announce Type: cross Abstract: Computational models of the human heart are widely used to study electromechanical and fluid-dynamical cardiac function and to support applications such as in silico clinical trials.
By Francesco Fabbri, Martino Andrea Scarpolini, Paolo Ciancarella, Francesco Tudisco, Roberto Verzicco, Alessandro Ricci, Francesco Viola
PPCAR-Net is a neural network that reconstructs 3‑D coronary artery centrelines and radii from a sparse set of X‑ray angiographic views. It predicts a branch‑structured centreline-and‑radius representation directly, avoiding explicit point matching or triangulation. The method refines geometry and radius estimates using projection‑guided refiners and achieves real‑time performance with strong centreline accuracy, especially for the right coronary artery.
By Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
arXiv:2606. 26718v1 Announce Type: new Abstract: Cardiac magnetic resonance imaging (CMR) captures rich spatiotemporal information about ventricular structure and motion, but conventional risk models use only a few image-derived indices from selected cardiac phases.
By David Br\"uggemann, Ekaterina Krymova, Firat \"Ozdemir, Jochen von Spiczak, Sebastian Kozerke, Samia Mora, Robert Manka, Mathieu Salzmann, Olga V. Demler
arXiv:2607. 04069v1 Announce Type: cross Abstract: Cardiac cine Magnetic Resonance Imaging (MRI) is a critical diagnostic tool that provides dynamic insights for radiologists.
By Donghang Lyu, Marius Staring, Yiming Dong, Keupp Jochen, Hildo J. Lamb, Mariya Doneva
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
arXiv:2606. 02639v1 Announce Type: cross Abstract: We identify and resolve a previously unreported failure mode in TensoRF when applied to X-ray attenuation fields: the default density shift of -10, originally introduced for RGB scene reconstruction, suppresses density gradients and prevents sparse-view medical reconstruction regardless of learning rate or regularization strategy.
By Spoorthi M, Suja Palaniswamy
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao