Hugging Face Trending Papers

RIQE: a NIQE-style reference model for Computed Tomography

arXiv Computer Vision
Oct 2

RIQE: a NIQE-style reference model for Computed Tomography

The paper introduces RIQE, a reference-free image quality evaluator for computed tomography that mirrors the NIQE framework used for photographs. Trained on 3,792 full‑dose CT slices from 158 patients, RIQE consistently ranks reduced‑dose reconstructions lower than their full‑dose counterparts and correctly identifies increased noise levels, but its preferences for filtered images do not align with lesion visibility. The authors caution that RIQE should not be the sole metric for selecting or tuning denoising algorithms.

By Fabio Mattiussi
arXiv AI
Sep 15

Physically Aware Radiomics Without Interpolation: Disentangling Voxel Geometry and Signal Modification in CT and MRI

The study introduces a voxel-spacing-aware radiomic framework that incorporates physical geometry into texture computation without resampling, modifying PyRadiomics to preserve native image signals. Four extraction configurations—native non-resampled (NR), isotropic resampling (RS), voxel-spacing-aware (VS), and fake-isotropic preprocessing (FK)—were compared across 685 CT pulmonary nodules and 209 MRI breast cases, evaluating 196 radiomic descriptors. Results show that VS closely matches NR (median ICC(A,1) ≈0.998) while RS and FK exhibit lower agreement, indicating that spacing metadata alone can significantly influence radiomic features.

By David Corral Fontecha, Juan Miranda Bautista, Pablo Menendez Fern\'andez-Miranda, Sergio Rubio-Mart\'in, Lara Lloret Iglesias, Jose A. Vega
arXiv AI
Oct 16

Towards Better Aligned LLM Judges for Radiology Report Evaluation across Modalities and Anatomies

The paper evaluates large language model (LLM) judges for radiology report assessment across multiple imaging modalities and anatomical regions, comparing four existing metrics (RadFact, GREEN, FineRadScore, CRIMSON) with a new metric called VERT. GREEN emerges as the most robust among current metrics, while VERT improves correlation with radiologist judgments by up to 26% over GREEN. The study also shows that ensembling and lightweight fine‑tuning of the Qwen3‑30B model can yield additional performance gains and significant latency reductions.

By Federica Bologna, Jean-Philippe Corbeil, Matthew Wilkens, Asma Ben Abacha
arXiv Computer Vision
Sep 11

Spectral Adapters for Segment Anything Model-based Segmentation of Colorectal Liver Metastases in Computed Tomography

The paper introduces two lightweight spectral adapters—Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA)—to adapt the Segment Anything Model (SAM) for accurate segmentation of colorectal liver metastases in contrast‑enhanced CT scans. SiGA achieves the highest single‑point Dice score of 0.77 and performs comparably to a 3D nnU‑Net baseline under no‑prompt inference, while DiSECT requires only 0.14 million trainable parameters. The study evaluates the adapters on 446 CT volumes across various prompting regimes, demonstrating that spectral adapters can efficiently adapt SAM with limited trainable parameters while maintaining strong segmentation accuracy.

By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen, Yun Shin Chun, HyunSeon Christine Kang, Richard K. G. Do, Amber L. Simpson
arXiv AI
Sep 1

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

arXiv:2608.29348v1 Announce Type: new Abstract: Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but...

By Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To, M\'at\'e Sik, C\'edric H\'emon, Thomas Weikert, Martin Segeroth
arXiv Computer Vision
Sep 1

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

arXiv:2608.28716v1 Announce Type: cross Abstract: Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent impr...

By Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten, L. D. Kampmeijer, Joost Nederend, Fons van der Sommen
arXiv Computer Vision
Sep 16

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.

By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu