RIQE: a NIQE-style reference model for Computed Tomography
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
arXiv:2609.16032v1 Announce Type: cross Abstract: Diffusion-based artifact detectors score whole-slide image patches by reconstruction error under a model fine-tuned on clean tissue. We show that con...
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
The paper introduces two lightweight spectral adapters—Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA)—to adapt the Segment Anything Model (SAM) for accurate segmentation of colorectal liver metastases in contrast‑enhanced CT scans. SiGA achieves the highest single‑point Dice score of 0.77 and performs comparably to a 3D nnU‑Net baseline under no‑prompt inference, while DiSECT requires only 0.14 million trainable parameters. The study evaluates the adapters on 446 CT volumes across various prompting regimes, demonstrating that spectral adapters can efficiently adapt SAM with limited trainable parameters while maintaining strong segmentation accuracy.
The study introduces a voxel-spacing-aware radiomic framework that incorporates physical geometry into texture computation without resampling, modifying PyRadiomics to preserve native image signals. Four extraction configurations—native non-resampled (NR), isotropic resampling (RS), voxel-spacing-aware (VS), and fake-isotropic preprocessing (FK)—were compared across 685 CT pulmonary nodules and 209 MRI breast cases, evaluating 196 radiomic descriptors. Results show that VS closely matches NR (median ICC(A,1) ≈0.998) while RS and FK exhibit lower agreement, indicating that spacing metadata alone can significantly influence radiomic features.
arXiv:2608. 08046v1 Announce Type: new Abstract: Text-conditioned chest X-ray generation aims to synthesize realistic radiographs that faithfully depict specified findings.
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.