arXiv:2608.30835v1 Announce Type: cross
Abstract: Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are c...
By Konstantinos Moutselos, Ilias Maglogiannis
arXiv:2607. 05965v1 Announce Type: cross Abstract: Vascular computed tomography datasets are commonly annotated only once per scan, yielding the pervasive yet under addressed problem of single mask annotation noise.
By Yinheng Zhu, Xiaowei Xu
The paper introduces SWIFT, a Swin V2‑based model pretrained on 10,444 3D CT volumes and fine‑tuned for rectal cancer segmentation on T2‑weighted MRI. Four configurations—full fine‑tuning (SWIFT), decoder compression (SWIFTe), low‑rank adaptation (SWIFTe‑LoRA), and a LoRA‑decoder ensemble (SWIFTe‑LDE4)—were evaluated on 247 cases, showing that SWIFTe reduces parameters by 70.1% while improving tumor detection and radiomic agreement. The study also demonstrates a trade‑off between detection and boundary agreement, and highlights that SWIFTe‑LDE4 achieves the lowest calibration errors after temperature scaling.
By Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan
The paper introduces "Destroy Me", a hybrid framework that generates realistic histopathology artifacts using Stable Diffusion and physics‑based modeling to create six common artifact types. Artifact realism is evaluated with KID and color Wasserstein metrics, and models trained on these augmented images outperform baselines on lung adenocarcinoma classification, achieving a 10.5% relative boost in macro F1‑score and a 15% increase in Cohen’s Kappa. The study highlights that selective, impact‑weighted augmentation is essential for enhancing robustness while preserving subtle diagnostic features.
By Zuzanna Krawczyk-Borysiak, Adam Krawczyk, Mateusz Miller, Gabriela Kaczmarek, S{\l}awomir Paku{\l}o, Ma{\l}gorzata Sok\'o{\l}, \.Zaneta Swiderska-Chadaj
arXiv:2606. 04419v1 Announce Type: cross Abstract: MRI provides excellent soft-tissue contrast without ionizing radiation, but long acquisition times increase patient discomfort while also raising exam costs and limiting scanner throughput.
By Arda Atal{\i}k, Sumit Chopra, Daniel K. Sodickson
arXiv:2609.09477v1 Announce Type: new
Abstract: Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a...
By Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang, Kai Ding