TransXplainRRG is a radiologist‑evaluated large vision‑language model that generates chest radiograph reports by combining a Swin Transformer vision encoder, a transformer‑based text encoder that incorporates patient medical history, and an LLM. The model uses an expert‑guided inside‑out approach to focus on abnormal findings and refine reports, aiming to balance high performance with explainability. Evaluated on MIMIC‑CXR and IU X‑Ray datasets, it achieves competitive standard metrics and higher GREEN scores (0.327 on MIMIC‑CXR, 0.605 on IU X‑Ray) than MAIRA‑2, with qualitative radiologist assessments supporting its clinical relevance.
By Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon
The paper investigates why CLIP-style contrastive image‑text pretraining fails in radiology, noting that zero‑shot performance peaks then degrades and large batches cause training collapse. By creating a synthetic CLEVR‑Radiology testbed that isolates overlapping clinical facts, the authors show that the paired‑identity target is structurally biased. They propose CorLIP, a minimal compatibility‑based correction that treats a report as positive when its clinical assertions agree with the image, which removes post‑peak degradation, enables stable large‑batch training, and improves performance across modalities.
By Yunhe Gao, Ashwin Kumar, Jiaming Liu, Chong Wang, Maya Varma, Fuying Wang, Stefania L. Moroianu, Louisa Fay, Sergios Gatidis, Akshay S. Chaudhari, Curtis Langlotz
ICGF-CXRMate is a framework that compresses heterogeneous patient data into a fixed set of clinical context tokens conditioned on chest X‑ray images. These tokens are selectively fused with visual features via gated cross‑attention and also retained in the decoder prompt, yielding shorter prompts and higher report quality. Experiments on MIMIC‑CXR and MIMIC‑IV‑ED show significant gains in RadGraph‑F1, CXR‑BERT similarity, and BLEU‑4, while reducing prompt length by 22.9%.
By Vu Minh Tran, Thuc Huynh, Son Thanh Luu, Doanh C. Bui
CheXPoT is a post‑hoc visual verification framework that refines vision‑language model (VLM) generated chest radiograph reports by decomposing them into predicates, grounding each against DenseNet‑121 and Grad‑CAM evidence, and removing unsupported findings. On a held‑out set of 4,145 images, CheXPoT significantly improves precision and F1 scores across multiple CheXpert classes, boosting micro‑average precision from 19.2 % to 46.8 % and micro‑average F1 from 23.0 % to 49.4 %. The method also enhances performance for other VLM generators such as LLaVA‑Med and MAIRA‑2, demonstrating that inexpensive visual verification can correct hallucinations and improve report quality.
By Joey Guo, Rayan Ansari, Alaa Youssef
arXiv:2610.08813v1 Announce Type: new
Abstract: X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potent...
By Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang, Bo Jiang, Yaowei Wang, Yonghong Tian, Jin Tang
The paper evaluates large language model (LLM) judges for radiology report assessment across multiple imaging modalities and anatomical regions, comparing four existing metrics (RadFact, GREEN, FineRadScore, CRIMSON) with a new metric called VERT. GREEN emerges as the most robust among current metrics, while VERT improves correlation with radiologist judgments by up to 26% over GREEN. The study also shows that ensembling and lightweight fine‑tuning of the Qwen3‑30B model can yield additional performance gains and significant latency reductions.
By Federica Bologna, Jean-Philippe Corbeil, Matthew Wilkens, Asma Ben Abacha
arXiv:2601.15891v4 Announce Type: replace
Abstract: Vision-language pretraining has driven progress in medical image representation learning, but it depends on paired image-text data and can inherit...
By Anas Anwarul Haq Khan, Mariam Husain, Pratik Jalan, Kshitij Jadhav
arXiv:2610.28289v1 Announce Type: new
Abstract: Radiologists interpret follow-up chest X-rays by comparing current and prior examinations to identify new, resolved or progressing findings. Most repor...
By Sike Xiang, Shuang Chen, Julie Cox, Amir Atapour-Abarghouei
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
arXiv:2610.29152v1 Announce Type: cross
Abstract: A generated chest radiograph can be useful as declared augmentation, but the same image becomes unsupported evidence when submitted as the record of...
By Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
The paper introduces RadCarve, a method that generates radiology reports by carving them into units based on anatomical region sets derived from existing statement-region correspondences. RadCarve’s planner predicts unit existence and region composition using composition-specialized query banks, while the generator produces each unit’s text conditioned on the joint visual evidence of its predicted region set. The approach outperforms strong baselines, improving CXRFEScore by 9.4% and achieving 2.4× higher end-to-end binding F1, while also delivering leading report-generation results on Chest ImaGenome and PadChest-GR with significantly fewer parameters.
By Jinwei Yang, Junhao Chen, Jianwei Zhao, Zhonghan Xu, Hong Cheng, Ling Wang
arXiv:2608. 03890v1 Announce Type: cross Abstract: A clinically useful chest X-ray system must go beyond fluent report generation: it should classify findings with tunable decision thresholds, localize them spatially, and derive the anatomical measurements upon which many diagnoses depend.
By Mercy Prasanna Ranjit, Anirban Porya, Sathvik Joel, Niharika Vadlamudi, Nikhilesh Chowdary Eathamukkala, Prasanth V V, Abhyuday Kumara Swamy, Pranay Narhari Umredkar, Pradeep Narayan, Vivek Rajagopal, Tanuja Ganu