arXiv:2608.30835v1 Announce Type: cross
Abstract: Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are c...
By Konstantinos Moutselos, Ilias Maglogiannis
arXiv:2607. 05965v1 Announce Type: cross Abstract: Vascular computed tomography datasets are commonly annotated only once per scan, yielding the pervasive yet under addressed problem of single mask annotation noise.
By Yinheng Zhu, Xiaowei Xu
The paper introduces SWIFT, a Swin V2‑based model pretrained on 10,444 3D CT volumes and fine‑tuned for rectal cancer segmentation on T2‑weighted MRI. Four configurations—full fine‑tuning (SWIFT), decoder compression (SWIFTe), low‑rank adaptation (SWIFTe‑LoRA), and a LoRA‑decoder ensemble (SWIFTe‑LDE4)—were evaluated on 247 cases, showing that SWIFTe reduces parameters by 70.1% while improving tumor detection and radiomic agreement. The study also demonstrates a trade‑off between detection and boundary agreement, and highlights that SWIFTe‑LDE4 achieves the lowest calibration errors after temperature scaling.
By Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan
The paper introduces "Destroy Me", a hybrid framework that generates realistic histopathology artifacts using Stable Diffusion and physics‑based modeling to create six common artifact types. Artifact realism is evaluated with KID and color Wasserstein metrics, and models trained on these augmented images outperform baselines on lung adenocarcinoma classification, achieving a 10.5% relative boost in macro F1‑score and a 15% increase in Cohen’s Kappa. The study highlights that selective, impact‑weighted augmentation is essential for enhancing robustness while preserving subtle diagnostic features.
By Zuzanna Krawczyk-Borysiak, Adam Krawczyk, Mateusz Miller, Gabriela Kaczmarek, S{\l}awomir Paku{\l}o, Ma{\l}gorzata Sok\'o{\l}, \.Zaneta Swiderska-Chadaj
arXiv:2606. 04419v1 Announce Type: cross Abstract: MRI provides excellent soft-tissue contrast without ionizing radiation, but long acquisition times increase patient discomfort while also raising exam costs and limiting scanner throughput.
By Arda Atal{\i}k, Sumit Chopra, Daniel K. Sodickson
arXiv:2609.09477v1 Announce Type: new
Abstract: Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a...
By Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang, Kai Ding
arXiv:2607. 16888v1 Announce Type: cross Abstract: Deploying a medical imaging model that must later accommodate a modality it has never seen is a recurring practical problem: retraining the shared representation is expensive and destroys performance on the modalities already in service.
By Ranat Das Prangon, Istiaque Ahmed, Shajid Hasan Naim, Waseem Mustak Zisan, Hossain Md Shakhawat
arXiv:2607. 08794v1 Announce Type: cross Abstract: Sand boils on earthen levees are safety-critical defects, but pixel-level detection is limited by scarce annotations.
By Padam Jung Thapa, Abdullah Bin Naeem, Ayon Dey, Anav Katwal, Md Tamjidul Hoque
arXiv:2606. 03069v1 Announce Type: cross Abstract: Generalized segmentation of medical images prevents performance degradation when different imaging devices and clinical protocols are used across multiple domains.
By Aqsa Naseer, Maryam Bibi, Syeda Samiya Urooj, Muhammad Khurram Shahzad
arXiv:2607. 26765v1 Announce Type: cross Abstract: Background/Objectives: Dermoscopic skin lesion classifiers often lose accuracy under domain shift across imaging devices, illumination, and capture artifacts.
By Alexander Kozachok, Ilya Latyshev, Evgeny Karpulevich, Elena Kozachok, Egor Ushakov, Oleg Samovarov
arXiv:2608. 03990v1 Announce Type: new Abstract: Synthetic histopathology image generation has emerged as an approach that may address data scarcity in computational pathology, yet current evaluation methodologies may not fully assess synthetic data quality for medical applications.
By Seyed Kahaki, Shijie Li, Weijie Chen, Nicholas Petrick
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski