arXiv:2606. 13839v1 Announce Type: cross Abstract: Remote photoplethysmography (rPPG) transformers achieve low heart-rate error on benchmarks, yet their decisions remain opaque--a growing concern as rPPG moves toward clinical heart rate estimation.
By Louis Chen, Torbj\"orn E. M. Nordling
The paper introduces Heartian, a physiology‑aware framework that augments Gaussian head avatars with cardiac‑cycle‑dependent albedo modulation, enabling the encoding of remote photoplethysmography (rPPG) signals. By supervising with synchronized contact PPG, the method models the cardiac waveform as a sum of two Gaussians and learns per‑frame spatial residuals via a lightweight MLP. Experiments on 152 stationary recordings from UBFC‑rPPG, PURE, and MMPD show heart‑rate estimation errors as low as 0.29 bpm MAE and 0.38 % MAPE, while preserving reconstruction quality with negligible PSNR loss.
By Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Ak\c{s}it
The paper investigates 12‑class body‑only emotion recognition from skeleton motion using a leave‑performer‑out evaluation, where chance accuracy is 8.3% and a reproduced STGCN++ baseline scores 25.73% Macro‑F1. By ensembling eleven models with orthogonal error modes, the authors achieve 36.80% Macro‑F1, a 43% relative improvement over the baseline. They also introduce a tested explanation suite that demonstrates the ensemble’s decisions rely on motion‑grounded body‑region evidence, aligning strongly with Laban Movement Analysis attributes rather than classical kinematics, while showing diffuse temporal saliency.
By Naoto Nishida, Yoshio Ishiguro
arXiv:2607. 13738v2 Announce Type: replace-cross Abstract: Deep video models estimate left-ventricular ejection fraction (EF) from echocardiography with near-expert accuracy, and post-hoc attribution is increasingly used to certify that such models look at the right place.
By Hyunkyung Han, Min Jung Kim
The study examined how well specific physiological properties of contact photoplethysmography (PPG) can be recovered when converted to camera-derived remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while overall heart‑rate accuracy was modest, many dynamic properties (e.g., autocorrelation, spectral measures, Lyapunov exponents) showed little recording‑specific correspondence, and differences varied with skin tone and observation conditions. The results demonstrate that preserving individual recording characteristics depends on the property and conditions, and population‑level agreement does not guarantee individual‑level fidelity.
Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose $\unicode{x1F493}$Heartian, a physiology-aware...
The study evaluates how acquisition context and photoplethysmography (PPG) signals contribute to session‑calibrated blood pressure tracking using a wearable‑state model on 653 AuroraBP participants. Adding contextual information reduced mean absolute errors (MAEs) for systolic and diastolic BP by 0.436 mmHg and 0.126 mmHg, respectively, while PPG alone provided modest improvements. Exploratory follow‑ups with sensor‑history ensembles and pulse‑rate fusion yielded only slight gains, and a separate intraoperative model (VitalDB) showed limited PPG benefit.
By Farouk Ganiyu Adewumi, Timothy Oladunni
The study examined how well physiological properties from contact photoplethysmography (PPG) can be recovered by camera-based remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while heart‑rate estimates showed modest accuracy, other dynamic measures such as autocorrelation, spectral content, and Lyapunov exponents largely failed to preserve recording‑specific characteristics. They also observed that lighting and motion influence endpoint accuracy, yet these factors did not explain the lack of dynamical correspondence.
By Timothy Oladunni, Farouk Ganiyu-Adewumi
BiMa-ECGSR reconstructs a full 12‑lead ECG from reduced lead sets using a bidirectional Mamba state‑space encoder–decoder, offering both regression (BiMa‑SR) and diffusion (DiBiMa‑SR) variants. Trained on PTB‑XL, the models achieve high Pearson correlations—up to 0.979 for I+II+V1+V4—outperforming a least‑squares linear filter across 18 configuration–cohort pairs. A 12‑lead classifier trained on real ECGs attains macro AUROC scores within 0.004 of real ECGs when using reconstructions from three or four leads, and the model processes a 10‑second record in 45.8 ms on a GPU.
By Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi
The paper introduces three sanity checks to evaluate whether architectural changes to Transformers—specifically removing components of attention heads—are justified by meaningful statistics in internal representations. Applying these checks to self‑attention removal across nine pretrained models, the authors find that a significant portion of head‑value cosine alignment is explained by a causal null, that alignment varies with key‑value grouping, and that the effect of removing the own‑value direction improves validation loss in large models but not in smaller ones. The study demonstrates that large cosine alignment alone does not guarantee redundancy, and that the benefit of removing a specific direction depends on model size and architecture.
By Basavaraj R M, Aryan Bharat Kumar
PulseBound is a photoplethysmography (PPG) representation learner that enforces an explicit stored‑window information boundary, ensuring that encoder inputs depend only on a visible prefix and a content‑independent cutoff. By combining physiologically structured future‑beat prediction with prefix‑only normalization, suffix replacement, and aligned masking, PulseBound achieves stored‑suffix invariance, preventing changes in the stored suffix from affecting forecast context or predictions. Evaluated on MIMIC and VitalDB datasets, PulseBound reduces mean absolute error by over 22% compared to last‑visible‑beat persistence and outperforms seven other models on nine frozen linear‑probe and seven full‑fine‑tuning downstream tasks.
By Chenyang Xu, Donglin Xie, Xi Xiang, Xiaoyu Li, Yufan Lu, Jiqiun Gao, Yi Zhao, Xin-Yi Li, Guangpu Zhu, Zijian Wang, Xiwen Yang, Dezhen Wang, Lin Chen, Shenda Hong, Leilei Li
arXiv:2412.17540v2 Announce Type: replace
Abstract: Reflective photoplethysmography (PPG) has become the default sensing technique in wearable devices to monitor cardiac activity via a person's heart...
By Manuel Meier, Berken Utku Demirel, Christian Holz