The study examined how well physiological properties from contact photoplethysmography (PPG) can be recovered by camera-based remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while heart‑rate estimates showed modest accuracy, other dynamic measures such as autocorrelation, spectral content, and Lyapunov exponents largely failed to preserve recording‑specific characteristics. They also observed that lighting and motion influence endpoint accuracy, yet these factors did not explain the lack of dynamical correspondence.
By Timothy Oladunni, Farouk Ganiyu-Adewumi
The study evaluates how acquisition context and photoplethysmography (PPG) signals contribute to session‑calibrated blood pressure tracking using a wearable‑state model on 653 AuroraBP participants. Adding contextual information reduced mean absolute errors (MAEs) for systolic and diastolic BP by 0.436 mmHg and 0.126 mmHg, respectively, while PPG alone provided modest improvements. Exploratory follow‑ups with sensor‑history ensembles and pulse‑rate fusion yielded only slight gains, and a separate intraoperative model (VitalDB) showed limited PPG benefit.
By Farouk Ganiyu Adewumi, Timothy Oladunni
arXiv:2605.10871v3 Announce Type: replace-cross
Abstract: We present Attractor-Vascular Coupling Theory (AVCT), a theory-guided framework for deriving interpretable blood pressure (BP) predictors fro...
By Timothy Oladunni, Farouk Ganiyu Adewumi
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fus...
Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about...