arXiv:2607. 23343v1 Announce Type: cross Abstract: Intraoperative 2D/3D registration aligns preoperative CT volumes with intraoperative X-ray or fluoroscopic images and is essential for image-guided interventions.
By Minheng Chen, Youyong Kong
UniReg is a conditional unified model for medical image registration that adapts deformation field estimation based on anatomical priors, registration type constraints, and instance-specific features. It combines the precision of task‑specific learning with the generalization of traditional optimization, enabling effective alignment across diverse CT and MR scenarios within a single framework. Experiments show UniReg outperforms state‑of‑the‑art learning‑based methods in accuracy while providing strong cross‑scenario generalization and reducing training cost and model redundancy.
By Zi Li, Jianpeng Zhang, Tai Ma, Tony C. W. Mok, Yan-Jie Zhou, Zeli Chen, Xianghua Ye, Le Lu, Cheng Chen, Dakai Jin
The paper introduces M2CG, a one-pass deformable image registration network that replaces recursive refinement with multi-level, multi-space contextual guidance. M2CG performs progressive pyramid registration within a single iteration, leveraging cues from previous, current, and subsequent steps across image, image feature, segmentation, and segmentation feature spaces. It achieves state‑of‑the‑art results on eight public medical datasets in both unsupervised and semi‑supervised settings, challenging the prevailing reliance on recursive architectures.
By Yue Lin, Shenghai Wu, Mingyuan Meng
nnFoundation introduces complementary convolutional and transformer-based 3D foundation models for radiology, trained on 2.1 million CT, MRI, and PET volumes from 125 datasets. The models are evaluated on 108 tasks—including segmentation, detection, classification, report generation, and image retrieval—under domain shift, low-data, and low-compute scenarios, consistently outperforming prior 3D foundation models and training from scratch. Performance varies by task type, with convolutional models excelling at spatially localized tasks and transformer models at global semantic reasoning, and dynamic alignment with dataset characteristics further enhances transferability.
By Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp, Maximilian Rokuss, Elisa Stegmeier, Philipp Schader, Dasha Trofimova, Raphael Stock, Kim-Celine Kahl, Stephen Schaumann, Selen Erkan, David Zimmerer, Stefan Denner, Moritz Langenberg, Sebastian Ziegler, Katharina Eckstein, Maximilian Fischer, Jonathan Suprijadi, B\'alint Kov\'acs, Benjamin Hamm, Anand Deshpande, Dimitrios Bounias, Nico Disch, Shuhan Xiao, Jessica K\"achele, Jan Sellner, Rajesh Baidya, Jeremias Traub, Lars Kr\"amer, Maximilian Zenk, Tim R\"adsch, Stefan Dvoretskii, Robin Peretzke, Jonathan Deissler, Alexandra Ertl, Partha Ghosh, Kris Dreher, Stefan Dinkelacker, Annika Reinke, Evangelia Christodoulou, Numan Saeed, Yoland Savriama, Santiago Estrada, David K\"ugler, Laura Alexandra Daza Barragan, Cristina Isabel Gonzalez Osorio, Jan Peeken, Michael Baumgartner, Marvin Teichmann, Guillaume Chabin, Matthias Kirchler, Valentin Koch, for the ALFA study, Markus Hohenhaus, Dimitri Koslov, Nina Decker, Mohammad Yaqub, Arnd Heuser, Martin Reuter, Julia A. Schnabel, Tobias Heimann, Florin Ghesu, Paul Brachmann, Claus P. Heu{\ss}el, Alexander Radbruch, Gianluca Brugnara, Aditya Rastogi, Martha Foltyn-Dumitru, Heinz-Peter Schlemmer, Ignaz Reicht, Julius C. Holzschuh, Michael Bach, Bram Stieltjes, Kai Schlamp, Lena Maier-Hein, Marco Nolden, Ralf Floca, Paul F. J\"ager, Philipp Vollmuth, Fabian Isensee, Klaus H. Maier-Hein
The paper examines how residual misalignments from registration procedures introduce structured label noise in supervised synthetic CT (sCT) generation. It shows that voxel‑wise metrics are heavily influenced by the consistency between training and evaluation registrations, and that training with anatomically consistent registrations reduces variability and improves robustness. Introducing a perceptual loss based on a pretrained Segment Anything encoder yields sharper, more anatomically coherent sCT and highlights the need for anatomy‑oriented evaluation.
By Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
The paper introduces an unsupervised domain adaptation framework that aligns redundancy-reducing features to enable accurate 3D segmentation of cone-beam CT (CBCT) without target-domain annotations or inference-time adaptation. The method is architecture-agnostic, working with both CNN-based and ViT-based foundation models, and is evaluated on two liver segmentation benchmarks for interventional vascular procedures and radiation therapy. Results show that even large pretrained segmentation networks need explicit feature-space bridging to generalize across diagnostic CT and CBCT, and the proposed approach consistently outperforms existing pretrained foundation models and UDA strategies.
By Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori
arXiv:2606. 06950v1 Announce Type: cross Abstract: Three-dimensional models are widely assumed preferable for volumetric medical imaging, yet their practical value depends on whether performance gains justify added computational cost and complexity.
By Md Enamul Hoq, Sharafat Hossain, Imraul Emmaka, Linda Larson-Prior, Lawrence Tarbox, Jonathan Bona, Donald Johann Jr. and Fred Prior
Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Altho...
3D point cloud registration in laparoscopic surgery estimates the transformation between an intraoperative organ reconstructed from video and its preoperative mesh. Because ground-truth transformations are unavailable for real data, supervised networks are trained on synthetic organ pairs.
XGLASS is a method that transfers expertise from 2D X‑ray vision‑language models to 3D CT volumes by using disease‑conditioned importance maps derived from radiologist gaze on X‑rays. By aligning these gaze priors with coronal CT projections, XGLASS predicts a disease‑specific ordering of axial slices, prioritizing diagnostically relevant slices. The approach achieves a top‑10 hit rate of up to 75.9% on a 240‑slice scan and reduces downstream model calls by 87.5% while improving F1 scores, making it a lightweight preselector for volumetric CT analysis.
By Michael Gl\"ockler, Timo Ropinski
arXiv:2608. 05960v1 Announce Type: cross Abstract: Routine CT interpretation is inherently comprehensive, capturing incidental findings across the entire scan volume.
By Maulik Chevli, Johannes Brandt, Rickmer Braren, Daniel Rueckert, Philip M\"uller
arXiv:2609.15669v1 Announce Type: cross
Abstract: Multimodal image registration is a key component of many clinical workflows, yet it remains challenging because corresponding anatomical structures o...
By Matteo Barbieri, Giammarco La Barbera, Juan Pablo De La Plata, Sabine Sarnacki, Isabelle Bloch, Pietro Gori