The paper evaluates three machine‑learning fault detectors—gradient‑boosted trees, a convolutional neural network, and logistic regression—against a reference sequence‑current method on 9,022 simulated 90 kV line fault episodes. Using a protection‑oriented assessment framework that includes multiple window conditions, causal labeling, episode‑grouped cross‑validation, and a fixed security budget, the authors report near‑perfect AUC‑ROC (>0.999) but reveal that missed‑trip rates can reach 1.99 % and false‑trip rates 0.12–0.16 % per window, with nuisance assertions in 11.3–19.1 % of episodes. The study also finds that higher fault resistance correlates most consistently with missed trips and that a fault‑current gradient is only partially captured by waveform‑derived current.
whyItMatters":"The assessment demonstrates that high aggregate performance metrics can mask significant protection‑relevant errors, highlighting the need for protection‑oriented evaluation of ML fault detectors."
By Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2609.16744v1 Announce Type: new
Abstract: The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery...
By Julian Oelhaf, Georg Kordowich, Paula Andrea P\'erez-Toro, Tom\'as Arias-Vergara, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2510. 00831v2 Announce Type: replace Abstract: The increasing complexity of modern power systems, driven by the integration of inverter-based and distributed energy resources, challenges the reliability of conventional protection schemes and motivates the use of machine learning for protection tasks.
By Julian Oelhaf, Georg Kordowich, Changhun Kim, Paula Andrea P\'erez-Toro, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2606. 24298v1 Announce Type: cross Abstract: The increasing interest in data-driven methods for power system protection is accompanied by a lack of standardized, publicly available high-voltage waveform datasets that enable transparent and reproducible evaluation.
By Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
EvEMTBench is an open, executable, and versioned benchmark designed to standardize the evaluation of machine‑learning methods for power system protection. It defines 12 protection and event‑analysis functions across four grids (20–345 kV) as 24 scored tasks, enabling structured assessment under varied observability, distribution shifts, and cross‑grid transfer scenarios. The benchmark includes committed data partitions, leakage controls, and reproducible reporting, and demonstrates that wider observability does not always help, that shifted conditions expose hidden failures, and that fault detection transfers better than fault localization.
By Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
The paper introduces Distributionally Robust Conformal Safety Screening (DR‑CSS), a policy‑agnostic framework that uses historical data and a nominal simulator to pre‑deploy safety checks for new voltage control policies in active distribution grids. DR‑CSS constructs conformal safety intervals around simulated voltage trajectories, enlarging them to account for closed‑loop effects of the new policy. Experiments on IEEE 33‑bus and 141‑bus systems show that DR‑CSS successfully identifies all unsafe scenarios while adapting intervals to reduce false warnings.
By Sarra Bouchkati, Petros Ellinas, Adriana Geisler, Steffen Kortmann, Johanna Vorwerk, Spyros Chatzivasiliadis, Andreas Ulbig
The paper introduces a hybrid two‑stage machine learning pipeline for fault detection and classification in high‑voltage transmission networks. Stage 1 uses an Isolation Forest anomaly detector combined with an optional supervised binary detector, while Stage 2 applies a Random Forest multiclass classifier only to samples flagged by Stage 1. Feature engineering maps six raw channels to eighteen features, including zero‑sequence symmetrical components, achieving end‑to‑end accuracies of 95.8 % on the TLFaultDataset and 97.25 % on an independent single‑point dataset, surpassing federated benchmarks without GPU or federated infrastructure.
By Sahil Manikshete, Atharva Gujarathi, Thanh Long Vu, Akhtar Hussain, Van-Hai Bui
The paper introduces PoSE, a Bayesian posterior sampling method for distribution system state estimation that learns the distribution of substation injections via a neural network trained with flow matching. Unlike weighted least squares or supervised deep learning, PoSE preserves the full Bayesian structure and ensures every posterior sample satisfies the power flow equations. Experiments on IEEE 33‑bus and Iowa 240‑bus feeders show PoSE reduces injection error by up to 7.5% and provides more reliable uncertainty estimates than Gaussian priors or supervised estimators.
By Nan Lin, Peter Palensky, Pedro Vergara Barrios
The paper presents a machine‑learning framework for classifying power‑system contingencies into safe, moderate, or severe categories. Using Newton‑Raphson load flow data, the study applies SMOTE, PCA, and classifiers (KNN, Random Forest, SVM) to IEEE‑14 and IEEE‑30 bus systems, evaluating performance with precision, recall, and F1 score. Random Forest achieved the highest F1 scores, while PCA improved overall performance more than SMOTE, which boosted recall at the cost of some false positives.
By Joshua Salako, Folajimi Osikomaiya, Olakorede Olamiju
The paper tackles fault detection and stability assessment during power swings in a 9‑bus WSCC system using PSCAD/EMTDC. It extracts 3,286 statistical, temporal, spectral, and fractal features from 3‑phase relay data via three feature libraries, then prunes them to 18 key descriptors with Boruta, RFECV, and SHAP. Benchmarking 14 classifiers, Rotation Forest and SVM‑RBF achieve near‑perfect discrimination of fault types and swing stability, demonstrating that automated, library‑driven feature engineering combined with rigorous statistical testing yields highly accurate, interpretable models.
The study examines how machine‑learning fault detectors trained on data from specific relay locations perform when applied to other relays in a 110 kV transmission network. Using 50 ms windows and a multilayer perceptron, the authors evaluate all 64 source–target relay combinations and find that overall F1‑scores remain similar, but the false‑positive rate rises markedly while the false‑negative rate falls when models are transferred across relays. Analysis shows that models retain coarse bus‑group information, and that aggregate metrics can mask location‑specific changes in false‑alarm behavior, underscoring the need to assess error types separately for cross‑relay generalization.
By Nithin Pradeep Nadayil Kizhakkethil, Julian Oelhaf, Christian Bergler, Andreas Maier, Siming Bayer
arXiv:2608. 20181v1 Announce Type: cross Abstract: Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting.
By Julian Oelhaf, Georg Kordowich, Paula Andrea P\'erez-Toro, Christian Bergler, Johann J\"ager, Andreas Maier, Siming Bayer