The paper evaluates three machine‑learning fault detectors—gradient‑boosted trees, a convolutional neural network, and logistic regression—against a reference sequence‑current method on 9,022 simulated 90 kV line fault episodes. Using a protection‑oriented assessment framework that includes multiple window conditions, causal labeling, episode‑grouped cross‑validation, and a fixed security budget, the authors report near‑perfect AUC‑ROC (>0.999) but reveal that missed‑trip rates can reach 1.99 % and false‑trip rates 0.12–0.16 % per window, with nuisance assertions in 11.3–19.1 % of episodes. The study also finds that higher fault resistance correlates most consistently with missed trips and that a fault‑current gradient is only partially captured by waveform‑derived current.
whyItMatters":"The assessment demonstrates that high aggregate performance metrics can mask significant protection‑relevant errors, highlighting the need for protection‑oriented evaluation of ML fault detectors."
By Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2608. 20181v1 Announce Type: cross Abstract: Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting.
By Julian Oelhaf, Georg Kordowich, Paula Andrea P\'erez-Toro, Christian Bergler, Johann J\"ager, Andreas Maier, Siming Bayer
arXiv:2510. 00831v2 Announce Type: replace Abstract: The increasing complexity of modern power systems, driven by the integration of inverter-based and distributed energy resources, challenges the reliability of conventional protection schemes and motivates the use of machine learning for protection tasks.
By Julian Oelhaf, Georg Kordowich, Changhun Kim, Paula Andrea P\'erez-Toro, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
The study examines how machine‑learning fault detectors trained on data from specific relay locations perform when applied to other relays in a 110 kV transmission network. Using 50 ms windows and a multilayer perceptron, the authors evaluate all 64 source–target relay combinations and find that overall F1‑scores remain similar, but the false‑positive rate rises markedly while the false‑negative rate falls when models are transferred across relays. Analysis shows that models retain coarse bus‑group information, and that aggregate metrics can mask location‑specific changes in false‑alarm behavior, underscoring the need to assess error types separately for cross‑relay generalization.
By Nithin Pradeep Nadayil Kizhakkethil, Julian Oelhaf, Christian Bergler, Andreas Maier, Siming Bayer
arXiv:2609.16744v1 Announce Type: new
Abstract: The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery...
By Julian Oelhaf, Georg Kordowich, Paula Andrea P\'erez-Toro, Tom\'as Arias-Vergara, Andreas Maier, Johann J\"ager, Siming Bayer
arXiv:2308. 07867v4 Announce Type: replace-cross Abstract: The absence of formal performance guarantees in machine learning (ML) has limited its adoption for safety-critical power system applications, where confidence and interpretability are as vital as accuracy.
By Parikshit Pareek, Sidhant Misra, Deepjyoti Deka