The paper introduces TopKSigLIP, a vision‑language model tailored for mammography that tackles two key challenges: high‑resolution imaging and homogeneous radiology reports. It replaces standard CLIP training with a TopK‑Patch module that selects sparse high‑resolution patches likely to contain lesions, and a Sup‑sigmoid loss that uses soft labels from structured data instead of contrastive loss. TopKSigLIP outperforms existing open‑source mammography and general medical VLMs on zero‑shot tasks such as density assessment, BI‑RADS classification, finding subtyping, and cancer prediction, while also providing better lesion localization than Grad‑CAM.
By Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede, Mohammadreza Chavoshi, Judy Gichoya, Hari Trivedi
arXiv:2607. 12175v1 Announce Type: cross Abstract: X-ray tomography enables nondestructive characterization of material microstructures, while advances in micro-CT imaging have accelerated volumetric data acquisition and reconstruction.
By Pradyumna Elavarthi, Arun J. Bhattacharjee, Harrison Lisabeth, Anca Ralescu, Petrus H. Zwart, Dilworth Parkinson, Elizabeth G. Clark
arXiv:2606. 19934v1 Announce Type: cross Abstract: Current machine learning models commonly require large and well-annotated datasets.
By Marta Fernandez-Moreno, Margarita Guerrero, Rosalia Rementeria, Pablo Mesejo, Raul Moreno
arXiv:2610.15669v2 Announce Type: replace-cross
Abstract: Weak bag-level labels are widely available in computational pathology, whereas reliable instance-level annotations for whole-slide images rem...
By Chen Shu, Chengyang Zhang, Boyu Fu, Ting Yin, Wenchuan Zhang, Jie Chen, Yuhao Yi, Hong Bu
CADS introduces a unified data-model framework for whole-body CT segmentation, featuring a SNOMED-CT-referenced anatomical label space that harmonizes data from over 100 imaging centers. The dataset includes complete annotations of 167 structures across 22,022 CT volumes, and employs self-training with shape-informed quality control to generate high-quality pseudo-labels for sparsely annotated scans. Models trained on CADS demonstrate robust performance across distribution shifts, outperform state-of-the-art methods on 18 public datasets, and have been validated in an expert-reviewed oncology cohort of 2,864 CTs.
By Murong Xu, Fernando Navarro, Maksym Fritsak, Ibrahim Ethem Hamamci, Suprosanna Shit, Bastian Wittmann, Sezgin Er, Sebastian M. Christ, Ezequiel de la Rosa, Julian Deseoe, Robert Graf, Hendrik M\"oller, Anjany Sekuboyina, Jan C. Peeken, Sven Becker, Giulia Baldini, Johannes Haubold, Felix Nensa, Ren\'e Hosch, Nikhil Mirajkar, Saad Khalid, Stefan Zachow, Marc-Andr\'e Weber, Georg Langs, Jakob Wasserthal, Mehmet Kemal Ozdemir, Andrey Fedorov, Ron Kikinis, Stephanie Tanadini-Lang, Jan S. Kirschke, Stephanie E. Combs, Tamaz Amiranashvili, Bjoern Menze
arXiv:2609.31431v1 Announce Type: new
Abstract: Accurate segmentation of axons in 3D microscopy data is important for analyzing white-matter organization, but dense ground truth labels are expensive...
By Edward Gaibor, Kyriaki-Margarita Bintsi, Carmen Luz Leiva Ureta, Zayneb Bellatif, Chiara Maffei, Wenze Li, Elizabeth Hillman, Ya\"el Balbastre, Anastasia Yendiki
arXiv:2606. 03180v1 Announce Type: cross Abstract: Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows.
By Jonggwon Park, Seongeun Lee, Junhyun Park, Hannah Yun, Hyunwoong Kim, Sohyun Jeong, Hyewon Kang, Byungmu Yoon, Kyoyun Choi
The study evaluates four deep‑learning segmentation architectures—Unet, PSPNet, Linknet, and FPN—paired with six pre‑trained encoders to predict COVID‑19 lesions in CT images. Experiments on three COVID‑19 CT datasets show high accuracy, achieving a maximum binary F1‑score of 98% and multi‑class F1‑scores of 75% and 77%. The work aims to provide a standardized performance benchmark for medical image segmentation and a reference for other imaging scenarios.
By Sarmad Khan, Basim Azam, Arslan Shaukat
Instance-Guided Report Anchoring (IGRA) is a model-agnostic module that links each abnormality instance in a chest CT to the corresponding finding in a radiology report during training, while discarding text components at inference. By reformulating free-text grounding as multi-label volumetric segmentation, IGRA allows all abnormality categories to be predicted in a single image-only forward pass. The method improves Dice scores by 22.5% over the strongest image-only baseline and matches state‑of‑the‑art performance on single-finding subsets, with consistent gains across multiple 3D segmentation backbones and datasets.
By Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan, Xueqi Guo, Sepehr Farhand, Yoshihisa Shinagawa, Gerardo Hermosillo, Chaowei Wu
arXiv:2609.25850v1 Announce Type: new
Abstract: Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-s...
By Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
CLARiTy is a vision transformer model that jointly performs multi‑label classification and weakly‑supervised localization of chest X‑ray pathologies. It uses class‑specific tokens to produce attention maps and a SegmentCAM module to refine foreground segmentation with anatomical priors. Trained on NIH ChestXray14 image‑level labels and distilled from a ConvNeXtV2 teacher, CLARiTy achieves competitive classification and strong localization, especially for small pathologies, outperforming prior methods by up to 50.7% relative Macro IoU accuracy.
By John M. Statheros, Hairong Wang, Richard Klein
The paper introduces a reference-guided data curation method for training 3D medical vision‑language models. By using a small, high‑quality reference set to extract quality signals from large, uncurated image‑report pools and aggregating these signals into a single ranking, the authors can select a subset of data that yields competitive zero‑shot disease classification performance. Experiments on 35k 3D abdominal CT pairs and 58k 2D chest X‑ray pairs show that the curated models match or exceed baseline performance while using up to ten times less training data.
By Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel, Akshay S. Chaudhari