arXiv Computer Vision

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

The paper introduces a reference-guided data curation method for training 3D medical vision‑language models. By using a small, high‑quality reference set to extract quality signals from large, uncurated image‑report pools and aggregating these signals into a single ranking, the authors can select a subset of data that yields competitive zero‑shot disease classification performance. Experiments on 35k 3D abdominal CT pairs and 58k 2D chest X‑ray pairs show that the curated models match or exceed baseline performance while using up to ten times less training data.

arXiv Machine Learning
Aug 18

Comprehensive language-image pre-training for 3D medical image understanding

arXiv:2510. 15042v3 Announce Type: replace-cross Abstract: In the 3D medical image domain, vision-language pre-training is used to create vision-language encoders (VLEs) that can support radiologists by retrieving patients with similar abnormalities, predicting likelihoods of abnormality, or, with downstream adaptation, generating radiological reports.

By Tassilo Wald, Ibrahim Ethem Hamamci, Yuan Gao, Sam Bond-Taylor, Harshita Sharma, Maximilian Ilse, Cynthia Lo, Olesya Melnichenko, Anton Schwaighofer, Noel C. F. Codella, Maria Teodora Wetscherek, Klaus H. Maier-Hein, Panagiotis Korfiatis, Valentina Salvatelli, Javier Alvarez-Valle, Fernando P\'erez-Garc\'ia
arXiv Computer Vision
Aug 27

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

The paper introduces a label‑free method called AURCC for selecting the best foundational model for medical image classification when the target domain lacks labels. AURCC uses a pseudo‑label discrepancy computed by the SUDO framework to score models without fine‑tuning. Experiments on chest X‑ray data across three inter‑hospital shifts show that AURCC closely matches the true model ranking, outperforming simple source‑accuracy baselines especially when source data are limited.

By Juan I\~naki Larrea, Lucas Mansilla, Enzo Ferrante
arXiv Machine Learning
Jul 30

Rethinking Clinical Relevance in Chest X-ray Machine Learning: How Evaluation References Define Performance

arXiv:2607. 26333v1 Announce Type: cross Abstract: Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment.

By Panagiotis Fytas, Ian Selby, Clemens Karner, Judith Babar, Simon Baker, Jake Beckford, Timothy J. Sadler, Shahab Shahipasand, Arthikkaa Thavakumar, John Li Chen, Alex Sawer, Michael Roberts, Jonathan Weir-McCall, J. H. F. Rudd, Carola-Bibiane Sch\"onlieb, Anna Korhonen, Anna Breger
arXiv Computer Vision
Sep 22

CXR-LT 2026 Challenge: Multi-Center Long-Tailed and Zero Shot Chest X-ray Classification

The CXR‑LT 2026 Challenge introduces a multi‑center, long‑tailed chest X‑ray classification benchmark with over 145,000 radiologist‑annotated images from PadChest and NIH datasets. It defines two core tasks: robust multi‑label classification on 30 known classes and open‑world generalization to 6 unseen rare disease classes. The paper outlines data collection, annotation, solution strategies, and evaluates performance across head‑vs‑tail, calibration, and cross‑center gaps, noting that vision‑language models improve in‑distribution and zero‑shot performance but rare‑finding detection under multi‑center shift remains difficult.

By Hexin Dong, Yi Lin, Pengyu Zhou, Fengnian Zhao, Alan Clint Legasto, Juno Cho, Dohui Kim, Justin Namuk Kim, Mingeon Kim, Sunwoo Kwak, Gabriel Moy\`a-Alcover, Ky Trung Nguyen, Thanh-Huy Nguyen, Ha-Hieu Pham, Huy-Hieu Pham, Huy Le Pham, Nikhileswara Rao Sulake, Aina Tur-Serrano, Ruichi Zhang, Ang Zu, Adam E. Flanders, Zhiyong Lu, Ronald M. Summers, Mingquan Lin, Hao Chen, Yuzhe Yang, George Shih, Yifan Peng
arXiv Machine Learning
6d ago

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

The study fine‑tunes a pretrained 3D medical vision‑language model for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution. Two adaptation strategies—full fine‑tuning and parameter‑efficient fine‑tuning (PEFT)—both achieve strong performance (AUC 0.82/0.79, F1 0.71/0.70) despite cross‑institutional domain shift, with PEFT updating only ~1% of parameters. The work highlights the trade‑offs between rapid convergence and overfitting in full fine‑tuning versus the efficiency of PEFT, and shows that self‑supervised CT‑report contrastive learning can improve HCC classification without lesion‑level annotations.

By Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
arXiv Computer Vision
Sep 2

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

Instance-Guided Report Anchoring (IGRA) is a model-agnostic module that links each abnormality instance in a chest CT to the corresponding finding in a radiology report during training, while discarding text components at inference. By reformulating free-text grounding as multi-label volumetric segmentation, IGRA allows all abnormality categories to be predicted in a single image-only forward pass. The method improves Dice scores by 22.5% over the strongest image-only baseline and matches state‑of‑the‑art performance on single-finding subsets, with consistent gains across multiple 3D segmentation backbones and datasets.

By Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan, Xueqi Guo, Sepehr Farhand, Yoshihisa Shinagawa, Gerardo Hermosillo, Chaowei Wu
arXiv Computer Vision
Aug 28

DALE-CT: Depth-Aware 2D Slice Encoders Learn an Anatomical World Model of Chest CT

DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.

By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner
arXiv Computer Vision
Sep 4

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

The paper introduces TopKSigLIP, a vision‑language model tailored for mammography that tackles two key challenges: high‑resolution imaging and homogeneous radiology reports. It replaces standard CLIP training with a TopK‑Patch module that selects sparse high‑resolution patches likely to contain lesions, and a Sup‑sigmoid loss that uses soft labels from structured data instead of contrastive loss. TopKSigLIP outperforms existing open‑source mammography and general medical VLMs on zero‑shot tasks such as density assessment, BI‑RADS classification, finding subtyping, and cancer prediction, while also providing better lesion localization than Grad‑CAM.

By Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede, Mohammadreza Chavoshi, Judy Gichoya, Hari Trivedi