Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this...
SparseTokenGS is a Gaussian-based, feed-forward method for sparse-view cone-beam CT reconstruction that uses a reusable token pool to maintain scan-wide context during decoding. Anchor Token Fusion and Point-Token Attention query this shared pool at anchors and query coordinates, preserving local Gaussian priors while enabling reconstruction in a single forward pass without per-scan optimization. Experiments on chest, dental, volcanic rock, and chicken datasets show that SparseTokenGS achieves superior reconstruction quality, achieving 29.51 dB PSNR and 0.842 SSIM from only six dental projections and maintaining separable tooth-and-pulp structures for root‑canal localization.
By Zihan Deng, Zhenzhen Gong, Yujie Liu, Jiaxin Gong, Dingkun Liu, Kexian Xie, Yixing Huang, Peng Jin, Tianye Niu, Zhisheng Wang, Fenglin Liu, Hongming Shan, Lequan Yu
The paper introduces Conditional Diffusion Posterior Alignment (CDPA), a method that scales diffusion-based sparse‑view CT reconstruction to large 3D volumes by conditioning a 2D U‑Net diffusion model on an initial 3D reconstruction and enforcing data‑consistency alignment. CDPA addresses high memory demands, limited 3D training data, and slice‑wise inconsistencies, achieving state‑of‑the‑art performance on synthetic and real Cone Beam CT data. The authors also demonstrate that the same approach improves fast denoising U‑Nets, delivering near‑diffusion quality at a fraction of the computational cost.
By Luis Barba, Johannes Kirschner, Benjamin Bejar
Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts....
The paper introduces LiftXR, a geometry‑guided framework that first reconstructs a 3D anatomical layout from bi‑planar X‑ray images and then uses this layout to guide CT volume reconstruction. An anatomical parser refines the layout by analyzing the reconstructed CT, enabling region‑specific intensity calibration. Experiments on two public datasets show LiftXR surpasses recent X‑ray‑to‑CT methods and improves downstream segmentation performance.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free fram...
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
arXiv:2602.08727v2 Announce Type: replace-cross
Abstract: Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utili...
By Johannes Thalhammer, Tina Dorosti, Sebastian Peterhansl, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff
arXiv:2610.09253v1 Announce Type: new
Abstract: Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric info...
By Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
EUReCA is a geometry‑aware, feed‑forward model that reconstructs cone‑beam CT images from 8–100 projections without needing view‑specific retraining. It encodes each projection with a shared multiscale backbone, back‑projects features into 3‑D grids, aggregates variable views at fixed cost, and refines the volume using a global transformer and decoder. On simulated and real patient data, EUReCA outperforms existing feed‑forward and iterative methods, achieving high PSNR and superior performance across all tested view counts.
By Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai, Xiuxiu He, Laura Cervino, Jean Moran, Xiang Li, Tianfang Li, Yabo Fu
arXiv:2605.20470v2 Announce Type: replace-cross
Abstract: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noi...
By Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat, Khaled Z. Alawneh, Ahmad Awad Qandeel, Alessandro Perelli