FlowMoDL is an unrolled neural network designed for highly accelerated 4D flow MRI reconstruction, optimizing both anatomical magnitude and phase-derived velocity accuracy. It alternates a learned (3+1)D spatiotemporal denoiser with conjugate‑gradient data‑consistency updates, using a dual‑pathway conditioning scheme to handle acceleration factors from 10× to 50×. Trained with a deep‑supervision composite loss that penalizes velocity magnitude and angular errors, FlowMoDL outperforms classical and deep‑learning baselines on the multi‑center CMRx4DFlow dataset, achieving superior gradient‑step efficiency and robust convergence across all acceleration factors.
By Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber, Daniel Tenbrinck, Torsten Panholzer, Melanie Schaller, Jana Hutter
arXiv:2610.33695v1 Announce Type: new
Abstract: Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibi...
By Emiljo M\"ehillaj, Ender Konukoglu
arXiv:2609.00960v1 Announce Type: new
Abstract: Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data acro...
By Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring, Efe Ilicak
arXiv:2610.33124v1 Announce Type: cross
Abstract: 4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resoluti...
By Oliver Welin Odeback, Nerea Gonz\'alez-Aranceta, Sebasti\'an Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, Mia Bonini, David Nordsletten, Patrick Winter, Susanne Schnell, Tobias Granberg, Alexander Fyrdahl, David Marlevi
arXiv:2610.08109v1 Announce Type: new
Abstract: Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while prese...
By Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
The paper introduces CURRENT, a recurrent neural network that simultaneously performs spatial and temporal super‑resolution of 4D flow MRI velocity fields. Trained on synthetic data derived from computational fluid dynamics simulations embedded in real MRI backgrounds, CURRENT outperforms separate spatial or temporal SR models and improves relative pressure estimation. It also generalizes well to in‑vivo acquisitions, offering a unified solution for enhancing 4D flow MRI quality.
By Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
The paper introduces Isthmus, a technique that connects isolated training pairs in one-step flow maps to the main diagonal of the time triangle, thereby bounding the error of the one-step sampler. By adding only 5% of training pairs along the edge linking the one-step pair to the diagonal, Isthmus restores uncertainty and stability without changing the network or loss. Experiments on MRI reconstruction, face inpainting, and unconditional generation on CIFAR‑10 and ImageNet 32×32 show significant improvements in calibration, variance, and correlation with multi‑step samples.
By Luming Yang, Siqing Li, Haoxian Liu, Zhenyu Bu, Jiazheng Zhu, Alper Yilmaz
arXiv:2606. 00100v1 Announce Type: cross Abstract: Self-supervised deep learning-based methods have shown great promise for accelerated magnetic resonance imaging (MRI) reconstruction, achieving high image quality without requiring fully sampled data for training.
By Tongxi Song, Ziyu Li, Zihan Li, Wen Zhong, Congyu Liao, Yang Yang, Hua Guo, Wenchuan Wu, Qiyuan Tian
The paper presents a Deep Operator Network that reconstructs full‑field 4D mitral regurgitation hemodynamics from sparse planar velocity data and boundary pressure traces. The network is pretrained on a URANS database of eleven orifice phantoms and then fine‑tuned on new cases, achieving rapid predictions in minutes. While the adaptation improves flow topology in the observed plane, reconstruction error increases sharply with distance from that plane, limiting physical consistency in the surrounding volume.
By Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
Zero-Shot Self-Supervised Learning (ZS-SSL) has emerged as a promising paradigm for accelerated Magnetic Resonance Imaging (MRI) reconstruction, eliminating the reliance on fully-sampled external datasets. However, learning solely from a single under-sampled scan suffers from supervision scarcity and optimization instability, often leading to overfitting or artifacts.
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.