arXiv:2610.33695v1 Announce Type: new
Abstract: Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibi...
By Emiljo M\"ehillaj, Ender Konukoglu
arXiv:2609.21412v1 Announce Type: new
Abstract: Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem...
By Ruijie Huang
VariaFlow is an uncertainty‑aware flow‑matching framework for unsupervised anomaly detection in brain MRI. It generates high‑quality pseudo‑healthy reconstructions and estimates a predictive variance via an ensemble of mask‑guided restorations, normalizing residuals to distinguish genuine pathology from normal anatomical variation. Trained once on healthy data, VariaFlow achieves state‑of‑the‑art AUROC and AUPRC across stroke and tumor datasets, outperforming baselines by up to 50% and maintaining stability under domain shift.
By Arnela Hadzic, Martin Urschler, Cosmin I. Bercea
The paper introduces ISLA, an ensemble learning framework for acute ischemic stroke lesion segmentation in diffusion MRI, built on nnU‑Net principles with attention modules, deep supervision, and varied input resolutions. A semi‑supervised variant, ISLA‑MT, incorporates unlabeled target‑domain images. Both models outperform state‑of‑the‑art pre‑trained models on internal validation and external multicenter cohorts, showing superior generalization, especially for low‑contrast lesions, and run in about five seconds per case.
By Vincent Roca, Hakim Daouairi, Sevak Yepremian, Hilde Henon, Nicolas Martinage, Laurent Puy, Gr\'egory Kuchcinski, Martin Bretzner, Renaud Lopes
arXiv:2609.00960v1 Announce Type: new
Abstract: Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data acro...
By Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring, Efe Ilicak
arXiv:2609.38644v1 Announce Type: cross
Abstract: 4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the...
By Mengyuan Xue, Bochun Mei
The paper introduces FLEX‑MRI, a method that accelerates MRI reconstruction by partitioning the recovery process into a few finite intervals defined by progressive k‑space support changes. Instead of learning fine‑grained local dynamics, FLEX‑MRI directly learns the reconstruction change across each interval and employs stochastic exploration during inference to sample alternative transition paths. Experiments on multi‑coil MRI datasets demonstrate that FLEX‑MRI outperforms competing methods while keeping computational efficiency comparable to few‑step baselines.
By Muhammad Usama Mirza, Esin \"Ozt\"urk I\c{s}{\i}k, Tolga \c{C}ukur
arXiv:2605. 00941v5 Announce Type: replace Abstract: Flow matching provides a highly effective framework for generative modeling, yet estimating the uncertainty of its generated samples remains a fundamental challenge.
By Jiarui Xing, Song Wang, Jian Wang
arXiv:2607. 13188v1 Announce Type: new Abstract: Human cognition does not separate understanding and generation.
By Minh-Quan Le, Armand Comas, Alexandros Lattas, Stylianos Moschoglou, Pedro V\'elez, Amit Raj, Aaron Germuth, Thabo Beeler, Dimitris Samaras, Di Qiu
Human cognition does not separate understanding and generation. A teacher at a whiteboard speaks and draws $\textit{together}$, each modality reshapes the other.
SliceBridge is a new framework for repairing corrupted slice intervals in T1‑weighted MRI by using rectified flow matching conditioned on surrounding intact slices and their relative positions. It enforces through‑plane consistency by coupling slices within the interval through shared noise, flow time, and synchronized sampling, then reinserts the restored interval without altering other slices. In experiments on 9,877 brain MRIs and 581 external subjects, SliceBridge reduced slice‑to‑slice error by 32.9%–41.3% and improved SSIM across interval lengths, while lowering downstream segmentation volume estimation error from 1.95% to 1.05%.
By Jiheng Li, Michael E. Kim, Trent Schwartz, Gaurav Rudravaram, Derek B. Archer, Timothy J. Hohman, the Alzheimer's Disease Neuroimaging Initiative, Lianrui Zuo, Bennett A. Landman
arXiv:2610.08983v1 Announce Type: new
Abstract: Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability...
By Arnela Hadzic, Franz Thaler, Simon Johannes Joham, Martin Urschler