arXiv:2606. 00100v1 Announce Type: cross Abstract: Self-supervised deep learning-based methods have shown great promise for accelerated magnetic resonance imaging (MRI) reconstruction, achieving high image quality without requiring fully sampled data for training.
By Tongxi Song, Ziyu Li, Zihan Li, Wen Zhong, Congyu Liao, Yang Yang, Hua Guo, Wenchuan Wu, Qiyuan Tian
arXiv:2607. 06132v1 Announce Type: cross Abstract: Multi-Pool Chemical Exchange Saturation Transfer (CEST) MRI provides valuable metabolic information but is clinically limited by long acquisition times.
By Dexuan Li, Yupeng Wu, Chenglong Wang, Hanlin Liu, Hui Zhen, Jianqi Li, Guang Yang
arXiv:2603. 03710v3 Announce Type: replace-cross Abstract: Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness.
By Seunghoi Kim, Chen Jin, Henry F. J. Tregidgo, Matteo Figini, Daniel C. Alexander
arXiv:2603. 04438v3 Announce Type: replace-cross Abstract: Fully unsupervised deep generative modeling (FU-DGM) offers significant potential for compressively sampled magnetic resonance imaging (CS-MRI) reconstruction.
By Qingyong Zhu, Yumin Tan, Xiang Gu, Dong Liang
arXiv:2606. 00146v1 Announce Type: cross Abstract: Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability.
By Honglin Xiong, Yuxian Tang, Feng Li, Yulin Wang, Lei Xiang, Dinggang Shen, Qian Wang
arXiv:2508. 05321v4 Announce Type: replace-cross Abstract: Assume you encounter an inverse problem that shall be solved for a large number of data, but no ground-truth data is available.
By Laura Hellwege, Johann Christopher Engster, Moritz Schaar, Thorsten M. Buzug, Maik Stille
arXiv:2605. 24590v2 Announce Type: replace-cross Abstract: Low-light, long-exposure defocus deblurring remains a challenging problem due to the simultaneous presence of severe blur and complex biased noise.
By Ziyan Huang, Lang Wu, Hongji Wang, Yifei Liu, Dongliang Tang, Hongqiao Wang
arXiv:2607. 04069v1 Announce Type: cross Abstract: Cardiac cine Magnetic Resonance Imaging (MRI) is a critical diagnostic tool that provides dynamic insights for radiologists.
By Donghang Lyu, Marius Staring, Yiming Dong, Keupp Jochen, Hildo J. Lamb, Mariya Doneva
Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs.
X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete. While learned reconstruction methods such as the Learned Primal-Dual algorithm achieve strong performance, they typically rely on supervised training with access to ground-truth data, which is often unavailable in practice.
arXiv:2604. 27277v3 Announce Type: replace-cross Abstract: Brain MRI underpins a wide range of neuroscientific and clinical applications, yet most learning-based methods remain task-specific and require substantial labeled data.
By Yizhou Wu, Shansong Wang, Yuheng Li, Mojtaba Safari, Mingzhe Hu, Chih-Wei Chang, Harini Veeraraghavan, Xiaofeng Yang
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao