SparseTokenGS is a Gaussian-based, feed-forward method for sparse-view cone-beam CT reconstruction that uses a reusable token pool to maintain scan-wide context during decoding. Anchor Token Fusion and Point-Token Attention query this shared pool at anchors and query coordinates, preserving local Gaussian priors while enabling reconstruction in a single forward pass without per-scan optimization. Experiments on chest, dental, volcanic rock, and chicken datasets show that SparseTokenGS achieves superior reconstruction quality, achieving 29.51 dB PSNR and 0.842 SSIM from only six dental projections and maintaining separable tooth-and-pulp structures for root‑canal localization.
By Zihan Deng, Zhenzhen Gong, Yujie Liu, Jiaxin Gong, Dingkun Liu, Kexian Xie, Yixing Huang, Peng Jin, Tianye Niu, Zhisheng Wang, Fenglin Liu, Hongming Shan, Lequan Yu
Generating a 3D dental volume from a single panoramic radiograph (PXR) could provide a low-radiation alternative to Cone-Beam Computed Tomography (CBCT), but the problem is highly underdetermined: panoramic acquisition integrates 3D attenuation along curved X-ray paths into a 2D image, leaving depth-resolved anatomy unobserved. Existing implicit and generative approaches often produce oversmoothed geometry or anatomically inconsistent hallucinations, lacking geometry-driven supervision and relying on smooth representations unable to precisely localize sharp anatomical boundaries.
The paper presents a three‑stage framework to extend the field of view in dental cone‑beam CT scans that are limited by truncated detector configurations. First, an implicit neural representation estimates missing projection data; second, an iterative reconstruction generates a secondary volumetric image with better anatomical consistency; third, a fast diffusion model refines the image for enhanced quality. Experiments show reduced truncation artifacts and improved reconstruction of structures beyond the original field of view.
By Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish, Dorothea Dagassan-Berndt, Michael M. Bornstein, Philippe C. Cattin
Sparse-view computed tomography is a severely ill-posed inverse problem, where recent 3D Gaussian Splatting methods offer an efficient explicit representation for tomographic reconstruction. However, we find that projection-domain optimization can be misleading in this setting: the rendered projections may continue to improve while the reconstructed volume deteriorates.
Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this...
arXiv:2609.37605v1 Announce Type: cross
Abstract: Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-project...
By AmirEhsan Khorashadizadeh, Benjam\'in B\'ejar
The paper introduces a method for extremely sparse‑view computed tomography (xSV‑CT) that learns a pose‑aware diffusion prior from a single 2D projection per training sample. During inference, the diffusion process is guided by measured‑view fidelity, shared‑volume reprojection, and projection‑physics consistency to reconstruct 3D volumes from only 1, 4, or 8 views. Experiments on two public CT datasets show that this approach outperforms or matches baselines that rely on dense‑volume supervision, achieving superior novel‑view synthesis and competitive reconstruction quality.
By Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi, Imari Sato
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
arXiv:2608. 15246v1 Announce Type: cross Abstract: Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts.
By Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima
arXiv:2610.09579v1 Announce Type: new
Abstract: Trajectory optimisation for cone-beam computed tomography (CT) determines which information sparse-view scans acquire. Fixed candidate pools prevent of...
By Linda-Sophie Schneider, Simon Wittl, Gabriel Herl, Andreas Maier
Trajectory optimisation for cone-beam computed tomography (CT) determines which information sparse-view scans acquire. Fixed candidate pools prevent off-grid refinement and require new object-specific...
Sparse-view computed tomography (CT) reduces radiation dose and acquisition time but remains severely ill-posed because incomplete projections poorly constrain null-space information. Existing learnin...