arXiv AI By Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima

CG-GLORE: A Conjugate Gradient-Based Global-Local Regularization Network for Sparse-View CT Reconstruction

Read the original on arXiv AI →

arXiv:2608. 15246v1 Announce Type: cross Abstract: Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts.

Summary generated by The Flow from the publisher's feed. The full article lives at arXiv AI.

arXiv AI
Jun 16

LUCID: Learned Undersampling-Adaptive Consistency-Guided Inference with Deterministic Flow Matching for Sparse-View CT Reconstruction

arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.

By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
Hugging Face Trending Papers
Jun 29

A Dual-domain Refinement Network with FBP-based Jacobian Learning for Sparse-view Dual-Energy CT Material Decomposition

Dual-energy CT (DECT) exploits attenuation differences across different X-ray spectra to provide richer material information and has been widely used in medical imaging. While sparse-view acquisition can lower radiation exposure, it makes DECT material decomposition even more challenging, as the problem is nonlinear and ill-posed.

arXiv Machine Learning
Jul 15

GenDiff: A Dose and Anatomy Aware Diffusion Model with Structural Prior Refinement for Low-Dose CT Reconstruction and Generalization

arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.

By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
arXiv AI
Jul 31

PatchDenoiser: Parameter-efficient multi-scale patch learning and fusion denoiser for Low-dose CT imaging

arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.

By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
Hugging Face Trending Papers
Jun 25

Enabling self-supervised learned primal dual with Noise2Inverse

X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete. While learned reconstruction methods such as the Learned Primal-Dual algorithm achieve strong performance, they typically rely on supervised training with access to ground-truth data, which is often unavailable in practice.