arXiv:2610.14226v1 Announce Type: cross
Abstract: Purpose : To develop and evaluate CAPTOR, a deep-learning vision-language foundation model for oncologic chest-abdomen-pelvis (CAP) CT interpretation...
By S\'el\'ena Jean-Mactoux, Sophie Loizillon, Ghina Jardali, Amandine Cromb\'e, Nathalie Lassau, Alexandre B\^one
The paper presents a method that derives BI‑RADS descriptors from breast MRI segmentation masks and uses a large language model to generate natural‑language rationales grounded in those descriptors. A BI‑RADS decision tree with eight quantitative radiomic measurements, lesion size, and component count informs the descriptors, which are then verbalised by the model. Applying this framework to 1,506 cases in the MAMA‑MIA dataset produced 3,012 reproducible BI‑RADS rationales with high faithfulness (99.98%) and counterfactual accuracy (99.3%).
By Hrishikesh Singh, Aarti Sharma, Divyanshu Kumar, Millie Pant
The study evaluates the robustness of medical vision‑language models for tuberculosis screening on chest X‑rays by testing them across multiple datasets, prompts, and evaluation settings. Three specialized models (BioMedCLIP, CheXficient, MedSigLIP) and a general OpenCLIP model were audited on 12,200 images, producing 244,000 model–image–prompt scores. Results show that no model consistently outperforms others across all cohorts and reliability criteria, with prompt changes and control group composition significantly affecting AUROC, and that high training‑set performance does not reliably transfer to external cohorts.
By Mushir Akhtar, M. Tanveer, Mohd. Arshad
arXiv:2608. 07857v1 Announce Type: cross Abstract: Foundation models provide transferable CT representations, but predictions based directly on these embeddings are difficult to interpret.
By Fakrul Islam Tushar, Stephen Adamo, Geoffrey D. Rubin
arXiv:2608. 07543v1 Announce Type: cross Abstract: Background and Study Aims: Accurate optical diagnosis of colorectal polyps guides resection strategy and surveillance, with multimodal large language models (MLLMs) showing potential for image-based diagnosis.
By Joshua C. Vences, William T. Tran, Nikko Gimpaya, Catharine M. Walsh, Rishad J. Khan, Robert Bechara, Asher C. Wiggins, Celine N. Rousan, Kaitlyn V. G. L. Morgado, Angie Ibrahim, Kevin H. M. Kuo, Daniel von Renteln, Alexander Hann, Dennis L. Shung, Michael A. Scaffidi, Charles M\'enard, Joshua Landy, Samir C. Grover
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
MammoSeek is a mammography agent that mimics radiologists’ reading workflow by first forming a global impression of each breast and then selectively zooming into candidate regions on full‑resolution views. It uses a BI‑RADS assessment skill to assign categories and generate localized, lexicon‑structured reports for each breast, combining these with image‑model scores to decide recall. On both an internal (EMBED) and an external (VinDr‑Mammo) dataset, MammoSeek achieves exam‑level AUCs of 0.824 and 0.818, outperforming other MLLMs, mammography agents, and CNN classifiers, while selective zooming improves localization, structured‑report F1, and recall decisions at low cost.
By Haoyan Ding, Qian Wang, Lixia Wang, Debiao Li
arXiv:2608. 03079v1 Announce Type: cross Abstract: Breast core needle biopsy (CNB) is central to breast cancer diagnosis yet remains challenging because limited tissue sampling, lesion heterogeneity, and subtle morphologic overlap can obscure subtype distinctions.
By Ting Yin, Danning Li, Chen Shu, Xiaoxia Yao, Boyu Fu, Yujing Chang, Tianyu Shi, Mengna Feng, Jie Chen, Jing Fu, Xiuli Xiao, Tianlin Li, Mumin Shao, Jiaxin Bi, Wenchuan Zhang, Xiaoyan Wu, Xiao Han, Zhang Zhang, Yuhao Yi, Hong Bu
Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate...
The study compares 2D, 2.5D, and 3D residual networks for classifying pulmonary nodule malignancy risk using a retrospective LIDC‑IDRI cohort of 2,654 nodules. Models were trained with random initialization, momentum‑contrast pretraining, and mild data augmentation, and evaluated on patient‑disjoint splits. Augmented 2.5D models achieved the highest test Macro‑F1 (0.6537) and accuracy (0.6869), while 2D and 3D models performed lower, and pretraining generally reduced performance.
By Bahodir Nazarov, Zineb Gharib, Fatima Zazoul
The study evaluated ten chest X‑ray AI classification models on 12 datasets from six countries, focusing on image‑level classification and measuring specificity at 95% sensitivity. MAVL and MedKLIP achieved the highest specificity (≈0.37) but still produced many false positives, with performance dropping on institutional cohorts compared to public benchmarks. No single model excelled across all findings, countries, or lesion types, highlighting limited generalisability.
By Qinmei Xu, Yiheng Li, Wenya Zhao, Zihao Zhao, Chuanjun Xu, Ahmet Gorkem Er, Xianghao Zhan, Brittany Dashevsky, Mohammed Alawad, Marc von der St\"uck, Marvin Gazibari\'c, Daniel Truhn, Shunsuke Shibata, Ryosuke Horino, Mio Ito, Akio Hiwatashi, Suyu Li, Mengya Yang, Ya Liu, Zhiyuan Sun, Changsheng Zhou, Haruka Itakura, Xiao Li, Olivier Gevaert
The paper evaluates multimodal decision models, specifically CLEF and CLEF‑Flash, on 2,818 breast ultrasound images from three datasets (Dataset B, BUSI, BUS‑BRA). Using three different prompts—minimal labels, explicit classification, and sonographic criteria—the study reports accuracy, macro F1, balanced accuracy, precision, throughput, and latency. CLEF‑Flash with a clinical prompt achieves the highest accuracy across all datasets, while CLEF with a task‑guided prompt yields the best macro F1 and balanced accuracy on BUSI; however, all configurations underperform a majority‑class predictor on BUS‑BRA, highlighting frequent benign‑to‑malignant misclassifications.
By Tran Cao Minh, Hai Tran, Ha Minh Tan