arXiv AI By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Read the original on arXiv AI →

Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv Machine Learning
Nov 6

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

The study audits a class‑imbalance benchmarking protocol for multimodal chest X‑ray and EHR prediction using 29,083 MIMIC‑CXR images from 10,479 patients. It finds that record‑level splits create leakage: a simple lookup table can match the best model, and when evaluated on unseen patients all models collapse to predicting every case positive. After correcting for patient‑separated evaluation and refined labels, no imbalance strategy improves macro F2 beyond 0.01, tuned tree ensembles offer no advantage over logistic regression, and EHR variables alone remain at an all‑positive baseline, while image embeddings and diagnostic history provide the strongest signals.

By Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo
arXiv AI
Oct 27

Benchmarking Classification Tasks of Chest X-ray AI Across Multinational Public and Private Datasets: a retrospective diagnostic accuracy study

The study evaluated ten chest X‑ray AI classification models on 12 datasets from six countries, focusing on image‑level classification and measuring specificity at 95% sensitivity. MAVL and MedKLIP achieved the highest specificity (≈0.37) but still produced many false positives, with performance dropping on institutional cohorts compared to public benchmarks. No single model excelled across all findings, countries, or lesion types, highlighting limited generalisability.

By Qinmei Xu, Yiheng Li, Wenya Zhao, Zihao Zhao, Chuanjun Xu, Ahmet Gorkem Er, Xianghao Zhan, Brittany Dashevsky, Mohammed Alawad, Marc von der St\"uck, Marvin Gazibari\'c, Daniel Truhn, Shunsuke Shibata, Ryosuke Horino, Mio Ito, Akio Hiwatashi, Suyu Li, Mengya Yang, Ya Liu, Zhiyuan Sun, Changsheng Zhou, Haruka Itakura, Xiao Li, Olivier Gevaert
arXiv Computer Vision
5d ago

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

ProtoBridge-CLIP introduces a new framework that blends symmetric global image–report alignment with observation‑masked finding supervision and a soft relation objective over affirmed report concepts. The method aligns text‑derived finding prototypes with local visual tokens while excluding uncertain and unmentioned concepts from direct labels. Evaluations on multiple CT and chest‑radiograph benchmarks show consistent performance gains, achieving macro‑AUROC scores up to 91.4% on CheXpert and demonstrating robustness across retrieval, localization, and calibration tasks.

By Jinrui Wu, Yun Peng
arXiv AI
Nov 14

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

TransXplainRRG is a radiologist‑evaluated large vision‑language model that generates chest radiograph reports by combining a Swin Transformer vision encoder, a transformer‑based text encoder that incorporates patient medical history, and an LLM. The model uses an expert‑guided inside‑out approach to focus on abnormal findings and refine reports, aiming to balance high performance with explainability. Evaluated on MIMIC‑CXR and IU X‑Ray datasets, it achieves competitive standard metrics and higher GREEN scores (0.327 on MIMIC‑CXR, 0.605 on IU X‑Ray) than MAIRA‑2, with qualitative radiologist assessments supporting its clinical relevance.

By Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon