arXiv AI By Qinmei Xu, Yiheng Li, Wenya Zhao, Zihao Zhao, Chuanjun Xu, Ahmet Gorkem Er, Xianghao Zhan, Brittany Dashevsky, Mohammed Alawad, Marc von der St\"uck, Marvin Gazibari\'c, Daniel Truhn, Shunsuke Shibata, Ryosuke Horino, Mio Ito, Akio Hiwatashi, Suyu Li, Mengya Yang, Ya Liu, Zhiyuan Sun, Changsheng Zhou, Haruka Itakura, Xiao Li, Olivier Gevaert

Benchmarking Classification Tasks of Chest X-ray AI Across Multinational Public and Private Datasets: a retrospective diagnostic accuracy study

Read the original on arXiv AI →

The study evaluated ten chest X‑ray AI classification models on 12 datasets from six countries, focusing on image‑level classification and measuring specificity at 95% sensitivity. MAVL and MedKLIP achieved the highest specificity (≈0.37) but still produced many false positives, with performance dropping on institutional cohorts compared to public benchmarks. No single model excelled across all findings, countries, or lesion types, highlighting limited generalisability.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv Machine Learning
Sep 21

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

The study evaluates the robustness of medical vision‑language models for tuberculosis screening on chest X‑rays by testing them across multiple datasets, prompts, and evaluation settings. Three specialized models (BioMedCLIP, CheXficient, MedSigLIP) and a general OpenCLIP model were audited on 12,200 images, producing 244,000 model–image–prompt scores. Results show that no model consistently outperforms others across all cohorts and reliability criteria, with prompt changes and control group composition significantly affecting AUROC, and that high training‑set performance does not reliably transfer to external cohorts.

By Mushir Akhtar, M. Tanveer, Mohd. Arshad
arXiv AI
Sep 25

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.

By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
arXiv Machine Learning
Jul 30

Rethinking Clinical Relevance in Chest X-ray Machine Learning: How Evaluation References Define Performance

arXiv:2607. 26333v1 Announce Type: cross Abstract: Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment.

By Panagiotis Fytas, Ian Selby, Clemens Karner, Judith Babar, Simon Baker, Jake Beckford, Timothy J. Sadler, Shahab Shahipasand, Arthikkaa Thavakumar, John Li Chen, Alex Sawer, Michael Roberts, Jonathan Weir-McCall, J. H. F. Rudd, Carola-Bibiane Sch\"onlieb, Anna Korhonen, Anna Breger
arXiv Machine Learning
Aug 11

Auditing Medical Vision-Language Models on Chest Radiographs: Estimating Reference Agreement Across Institutions

arXiv:2608. 07550v1 Announce Type: cross Abstract: Vision-language models return structured chest-radiograph findings through interfaces exposing no confidence score, so a receiving institution cannot read off how far to trust an individual judgment.

By Pengyang Yu, Yiou Wang, Zhongping Dong, Sahraoui Dhelim, Chun-Mei Feng, M. Tahar Kechadi