arXiv Machine Learning

Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

arXiv AI
Oct 12

Medical foundation models converge less under label supervision

The study evaluates how well different medical foundation models agree on image embeddings by measuring mutual k‑nearest‑neighbor overlap across 750,000 images from 14 datasets and 18 public models. Results show that label‑supervised models converge the least, sharing only 6–10% of nearest neighbors, whereas models trained with self‑distillation, masked image modeling, or contrastive pretraining share up to 80%. The authors suggest that developers can select pretraining objectives to control convergence and recommend testing unlabeled images for nearest‑neighbor consistency before replacing a model.

By Soroosh Tayebi Arasteh, Sebastian Ziegelmayer, Mahshad Lotfinia, Lisa Adams, Sven Nebelung, Jakob Nikolas Kather, Daniel Truhn
arXiv Machine Learning
Jul 30

Rethinking Clinical Relevance in Chest X-ray Machine Learning: How Evaluation References Define Performance

arXiv:2607. 26333v1 Announce Type: cross Abstract: Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment.

By Panagiotis Fytas, Ian Selby, Clemens Karner, Judith Babar, Simon Baker, Jake Beckford, Timothy J. Sadler, Shahab Shahipasand, Arthikkaa Thavakumar, John Li Chen, Alex Sawer, Michael Roberts, Jonathan Weir-McCall, J. H. F. Rudd, Carola-Bibiane Sch\"onlieb, Anna Korhonen, Anna Breger
arXiv Machine Learning
Aug 18

On Cross-Validation for Hyperparameter Optimization of Deep Learning Image Classifiers

arXiv:2608. 14705v1 Announce Type: cross Abstract: Hyperparameter optimization (HPO) can materially affect the performance of deep learning (DL) image classifiers, but there is little empirical guidance on how to derive the validation signal that drives it, especially for the small sample sizes common in fields such as medical imaging.

By Ljubomir Buturovic (East Palo Alto, United States)
arXiv Machine Learning
Oct 22

From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for Vision-Language Model Weak Supervision Across Three Medical-Imaging Benchmarks

The study investigates when adding zero‑shot pseudo‑labels from vision‑language models (VLMs) to small expert‑labelled medical imaging datasets ceases to improve, and may even degrade, classifier performance. Across three benchmarks—PatchCamelyon, ISIC 2019, and NIH ChestX‑ray14—the crossover point occurs after roughly 20–50, 100, and 250–500 expert labels, respectively, with additional pseudo‑labels reducing macro‑AUC by up to 0.14 points. The analysis shows that the VLM’s labeling quality, rather than the student model size, limits performance, and a simple bias‑variance rule can predict the benefit of pseudo‑labels in most settings.

By Bruce Changlong Xu, Jose K. James, Alexander J. Ryu
arXiv Machine Learning
Nov 6

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

The study audits a class‑imbalance benchmarking protocol for multimodal chest X‑ray and EHR prediction using 29,083 MIMIC‑CXR images from 10,479 patients. It finds that record‑level splits create leakage: a simple lookup table can match the best model, and when evaluated on unseen patients all models collapse to predicting every case positive. After correcting for patient‑separated evaluation and refined labels, no imbalance strategy improves macro F2 beyond 0.01, tuned tree ensembles offer no advantage over logistic regression, and EHR variables alone remain at an all‑positive baseline, while image embeddings and diagnostic history provide the strongest signals.

By Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo
Hugging Face Trending Papers
Nov 9

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

The study evaluates whether combining multiple ImageNet‑pretrained convolutional networks and Vision Transformers improves chest X‑ray classification compared to a single chest‑radiograph‑pretrained foundation model. On NIH ChestX‑ray14, the EVA‑X‑S foundation model alone achieved a macro‑AUROC of 0.828, while a five‑model ensemble only reached 0.814—worse by about 1.4%—and required far greater latency and parameters. Even when the ImageNet backbones were fine‑tuned with the EVA‑X‑S recipe, the ensemble still lagged behind EVA‑X‑S, and no stacking strategy outperformed simple calibrated averaging.

arXiv Computer Vision
Nov 11

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

The study evaluates whether ensembles of ImageNet‑pretrained CNNs and Vision Transformers improve multi‑label chest X‑ray classification compared to a single chest‑radiograph foundation model, EVA‑X‑S. On NIH ChestX‑ray14, EVA‑X‑S alone achieved a macro‑AUROC of 0.828, while a five‑model ensemble scored 0.814—slightly lower and with much higher latency and parameter count. Across various fusion rules and training recipes, the ensemble never surpassed the fine‑tuned foundation model, and full‑stacking configurations also failed to outperform calibrated averaging.

By Aditya Seelaboyina, Irfan Khan
arXiv Computer Vision
Aug 27

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

The paper introduces a label‑free method called AURCC for selecting the best foundational model for medical image classification when the target domain lacks labels. AURCC uses a pseudo‑label discrepancy computed by the SUDO framework to score models without fine‑tuning. Experiments on chest X‑ray data across three inter‑hospital shifts show that AURCC closely matches the true model ranking, outperforming simple source‑accuracy baselines especially when source data are limited.

By Juan I\~naki Larrea, Lucas Mansilla, Enzo Ferrante