The study evaluates whether ensembles of ImageNet‑pretrained CNNs and Vision Transformers improve multi‑label chest X‑ray classification compared to a single chest‑radiograph foundation model, EVA‑X‑S. On NIH ChestX‑ray14, EVA‑X‑S alone achieved a macro‑AUROC of 0.828, while a five‑model ensemble scored 0.814—slightly lower and with much higher latency and parameter count. Across various fusion rules and training recipes, the ensemble never surpassed the fine‑tuned foundation model, and full‑stacking configurations also failed to outperform calibrated averaging.
By Aditya Seelaboyina, Irfan Khan
arXiv:2608.30467v1 Announce Type: new
Abstract: Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely...
By Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates...
arXiv:2609.37848v1 Announce Type: cross
Abstract: Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even...
By Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
arXiv:2608.21571v1 Announce Type: new
Abstract: Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage...
By Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson, Rowena Yip, Myvizhi Esai Selvan, Zeynep H. Gumus, Claudia Henschke, Robert J. Klein, Providencia Morales, Samuel M Aguayo, Ioana Danciu, Mayanka Chandrashekar
The study evaluates how well different medical foundation models agree on image embeddings by measuring mutual k‑nearest‑neighbor overlap across 750,000 images from 14 datasets and 18 public models. Results show that label‑supervised models converge the least, sharing only 6–10% of nearest neighbors, whereas models trained with self‑distillation, masked image modeling, or contrastive pretraining share up to 80%. The authors suggest that developers can select pretraining objectives to control convergence and recommend testing unlabeled images for nearest‑neighbor consistency before replacing a model.
By Soroosh Tayebi Arasteh, Sebastian Ziegelmayer, Mahshad Lotfinia, Lisa Adams, Sven Nebelung, Jakob Nikolas Kather, Daniel Truhn