The study evaluates whether ensembles of ImageNet‑pretrained CNNs and Vision Transformers improve multi‑label chest X‑ray classification compared to a single chest‑radiograph foundation model, EVA‑X‑S. On NIH ChestX‑ray14, EVA‑X‑S alone achieved a macro‑AUROC of 0.828, while a five‑model ensemble scored 0.814—slightly lower and with much higher latency and parameter count. Across various fusion rules and training recipes, the ensemble never surpassed the fine‑tuned foundation model, and full‑stacking configurations also failed to outperform calibrated averaging.
By Aditya Seelaboyina, Irfan Khan
arXiv:2608.30467v1 Announce Type: new
Abstract: Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely...
By Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates...
arXiv:2609.37848v1 Announce Type: cross
Abstract: Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even...
By Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
arXiv:2608.21571v1 Announce Type: new
Abstract: Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage...
By Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson, Rowena Yip, Myvizhi Esai Selvan, Zeynep H. Gumus, Claudia Henschke, Robert J. Klein, Providencia Morales, Samuel M Aguayo, Ioana Danciu, Mayanka Chandrashekar
The study evaluates how well different medical foundation models agree on image embeddings by measuring mutual k‑nearest‑neighbor overlap across 750,000 images from 14 datasets and 18 public models. Results show that label‑supervised models converge the least, sharing only 6–10% of nearest neighbors, whereas models trained with self‑distillation, masked image modeling, or contrastive pretraining share up to 80%. The authors suggest that developers can select pretraining objectives to control convergence and recommend testing unlabeled images for nearest‑neighbor consistency before replacing a model.
By Soroosh Tayebi Arasteh, Sebastian Ziegelmayer, Mahshad Lotfinia, Lisa Adams, Sven Nebelung, Jakob Nikolas Kather, Daniel Truhn
arXiv:2607. 04478v1 Announce Type: cross Abstract: Automated chest X-ray classification remains challenging due to severe class imbalance, co-occurring pathologies, and the loss of localized features in conventional architectures.
By Moshiur Rahman, Shafqat Alam, Tasnia Binte Mamun
arXiv:2607. 16888v1 Announce Type: cross Abstract: Deploying a medical imaging model that must later accommodate a modality it has never seen is a recurring practical problem: retraining the shared representation is expensive and destroys performance on the modalities already in service.
By Ranat Das Prangon, Istiaque Ahmed, Shajid Hasan Naim, Waseem Mustak Zisan, Hossain Md Shakhawat
The ReXGrounding Challenge, held at MICCAI 2026, focused on segmenting radiology findings in 3D chest CT scans based on report text. Using the ReXGroundingCT dataset, 48 teams from 15 countries submitted 760 models, with the best achieving a Dice score of 0.375 and a hit rate of 0.77—comparable to inter‑radiologist agreement. Despite this progress, challenges remain for non‑focal findings, multi‑instance cases, and accurate anatomical localization.
By Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens, Zirong Chen, Jiayu Wang, Xi Ouyang, Mingyang Yu, Weiqiu Jin, Xiaodan Ye, Dijia Wu, Kwang-Hyun Uhm, Inhwa Son, Rachel van 't Hull, Tim Veenboer, Cees Snoek, Kevin Groot Lipman, Daesung Kim, Junha Im, Youngjun Jun, Sangwon Lee, Katelyn Morrison, Adam Perer, Mijin Yun, Ali Piracha, Reem Alwasiah, Talal Yahyan, Abdulrahman Alamoudi, Mashael Alshehri, Rayan Alsager, Hannah Hancock, Anna M. Hunkem\"oller, Peter Youssef, Mona A. Alhammad, Afnan Aljumayan, Brecht Van Berkel, Eric Bijnens, Saud Alhussain, Maarten Steyvers, Rolf Symons, Bryan Eelen, Ayed Alaklubi, Maha Buraykan Alshammari, Amirah Fahad Alshammeri, Tomas Gilvydis, Ibrahim AlTurki, Monerah Almohideb, Ali Alburkani, Shahad Alhomaiani, Fatima Jabali, Maximilian Rokuss, Moritz Langenberg, Yannick Kirchhoff, Benjamin Hamm, Klaus Maier-Hein, Ibrahim Ethem Hamamci, Sezgin Er, Michael Moritz, Hassan R. Alomaish, Luyang Luo, Pranav Rajpurkar
The study investigates when adding zero‑shot pseudo‑labels from vision‑language models (VLMs) to small expert‑labelled medical imaging datasets ceases to improve, and may even degrade, classifier performance. Across three benchmarks—PatchCamelyon, ISIC 2019, and NIH ChestX‑ray14—the crossover point occurs after roughly 20–50, 100, and 250–500 expert labels, respectively, with additional pseudo‑labels reducing macro‑AUC by up to 0.14 points. The analysis shows that the VLM’s labeling quality, rather than the student model size, limits performance, and a simple bias‑variance rule can predict the benefit of pseudo‑labels in most settings.
By Bruce Changlong Xu, Jose K. James, Alexander J. Ryu
RespCCT and FreqCCT are compact convolutional transformer models designed for multi‑class respiratory disease classification from chest auscultation recordings. Trained from scratch on mel, constant‑Q, and cepstral images of 5‑second audio frames, they achieve high accuracy (98.13% and 97.58% respectively) while using far fewer parameters than large pretrained networks. The study also evaluates computational cost per pipeline stage, examines attribution map consistency, and demonstrates that a linear probe can identify the recording source with 95.8% accuracy.
By Auntor Chakma, Mst. Farhana Akter, Abu Henaf Rashid Ahmad Mufti, Asmana Yasmin
Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate...