MIRROR: Multimodal Intelligent Radiology Reasoning and Observation Reporter
arXiv:2608. 16709v1 Announce Type: cross Abstract: A radiologist reading a model's output faces two problems.
The study investigates when adding zero‑shot pseudo‑labels from vision‑language models (VLMs) to small expert‑labelled medical imaging datasets ceases to improve, and may even degrade, classifier performance. Across three benchmarks—PatchCamelyon, ISIC 2019, and NIH ChestX‑ray14—the crossover point occurs after roughly 20–50, 100, and 250–500 expert labels, respectively, with additional pseudo‑labels reducing macro‑AUC by up to 0.14 points. The analysis shows that the VLM’s labeling quality, rather than the student model size, limits performance, and a simple bias‑variance rule can predict the benefit of pseudo‑labels in most settings.
arXiv:2608. 16709v1 Announce Type: cross Abstract: A radiologist reading a model's output faces two problems.
arXiv:2606.15910v3 Announce Type: replace Abstract: An answer from a vision-language model (VLM) to a medical image question can be accepted without review only under a threshold bounding the error o...
arXiv:2609.37848v1 Announce Type: cross Abstract: Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even...
The paper introduces a label‑free method called AURCC for selecting the best foundational model for medical image classification when the target domain lacks labels. AURCC uses a pseudo‑label discrepancy computed by the SUDO framework to score models without fine‑tuning. Experiments on chest X‑ray data across three inter‑hospital shifts show that AURCC closely matches the true model ranking, outperforming simple source‑accuracy baselines especially when source data are limited.
The study evaluates how well different medical foundation models agree on image embeddings by measuring mutual k‑nearest‑neighbor overlap across 750,000 images from 14 datasets and 18 public models. Results show that label‑supervised models converge the least, sharing only 6–10% of nearest neighbors, whereas models trained with self‑distillation, masked image modeling, or contrastive pretraining share up to 80%. The authors suggest that developers can select pretraining objectives to control convergence and recommend testing unlabeled images for nearest‑neighbor consistency before replacing a model.
arXiv:2606. 17710v1 Announce Type: cross Abstract: Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image.
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
The study evaluated ten chest X‑ray AI classification models on 12 datasets from six countries, focusing on image‑level classification and measuring specificity at 95% sensitivity. MAVL and MedKLIP achieved the highest specificity (≈0.37) but still produced many false positives, with performance dropping on institutional cohorts compared to public benchmarks. No single model excelled across all findings, countries, or lesion types, highlighting limited generalisability.
PRISM is a tile‑level benchmark for pathology foundation models that evaluates reliability across four dimensions: model choice, label fraction, calibration, and out‑of‑distribution transfer. It tests eight models on six datasets at six label fractions (1%–100%) with 864 linear probe runs, plus a five‑hospital Camelyon17 transfer study. The benchmark reveals four key phenomena, including the changing relationship between AUROC and calibration at low labels, collapse of linear probes on harder datasets, the impact of source‑domain labels on target calibration, and limitations of temperature scaling.
arXiv:2606. 15910v2 Announce Type: replace Abstract: A vision-language model can answer a question about a chest radiograph or a pathology slide fluently and confidently while barely using the image, relying instead on language priors.
The study evaluates the robustness of medical vision‑language models for tuberculosis screening on chest X‑rays by testing them across multiple datasets, prompts, and evaluation settings. Three specialized models (BioMedCLIP, CheXficient, MedSigLIP) and a general OpenCLIP model were audited on 12,200 images, producing 244,000 model–image–prompt scores. Results show that no model consistently outperforms others across all cohorts and reliability criteria, with prompt changes and control group composition significantly affecting AUROC, and that high training‑set performance does not reliably transfer to external cohorts.
arXiv:2608. 07550v1 Announce Type: cross Abstract: Vision-language models return structured chest-radiograph findings through interfaces exposing no confidence score, so a receiving institution cannot read off how far to trust an individual judgment.