arXiv:2509. 19671v3 Announce Type: replace Abstract: Public datasets of Chest X-Rays (CXRs) have long been a popular benchmark for developing machine learning (ML) computer vision models in healthcare.
By Andrew Wang, Jiashuo Zhang, Michael Oberst
The paper evaluates large language model (LLM) judges for radiology report assessment across multiple imaging modalities and anatomical regions, comparing four existing metrics (RadFact, GREEN, FineRadScore, CRIMSON) with a new metric called VERT. GREEN emerges as the most robust among current metrics, while VERT improves correlation with radiologist judgments by up to 26% over GREEN. The study also shows that ensembling and lightweight fine‑tuning of the Qwen3‑30B model can yield additional performance gains and significant latency reductions.
By Federica Bologna, Jean-Philippe Corbeil, Matthew Wilkens, Asma Ben Abacha
The study examines how differences in radiologists’ reporting styles—such as terminology, shorthand, formatting, and detail—affect the evaluation of AI-generated chest X‑ray reports. By quantifying the sensitivity of common metrics to these variations, the authors show that changes in reference reports can shift model rankings. They introduce a taxonomy of reporting variations and a rewriting method, ReRef, that preserves clinical meaning while altering style, and release a validated dataset of paired reference reports to aid future research.
By Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency, Pradeep Ravikumar, Zachary C. Lipton, Michael Oberst
RadRef is a new reference‑free metric for evaluating AI‑generated radiology reports by scoring report claims against image‑derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. On the ReXVal benchmark it achieves 73.1% agreement with radiologist rankings for non‑tied same‑radiograph pairs, comparable to leading reference‑based metrics, and shows strong performance on false findings and omissions. In a reader study of 100 model‑generated and 100 radiologist‑authored reports, RadRef’s Kendall’s tau‑b for omissions (0.295) is close to the inter‑reader agreement (0.386), and its false‑finding readout (RadRef‑FF) also matches reference‑based metrics without needing a reference.
By Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin, Chirag Agarwal
TransXplainRRG is a radiologist‑evaluated large vision‑language model that generates chest radiograph reports by combining a Swin Transformer vision encoder, a transformer‑based text encoder that incorporates patient medical history, and an LLM. The model uses an expert‑guided inside‑out approach to focus on abnormal findings and refine reports, aiming to balance high performance with explainability. Evaluated on MIMIC‑CXR and IU X‑Ray datasets, it achieves competitive standard metrics and higher GREEN scores (0.327 on MIMIC‑CXR, 0.605 on IU X‑Ray) than MAIRA‑2, with qualitative radiologist assessments supporting its clinical relevance.
By Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon
The paper introduces a label‑free method called AURCC for selecting the best foundational model for medical image classification when the target domain lacks labels. AURCC uses a pseudo‑label discrepancy computed by the SUDO framework to score models without fine‑tuning. Experiments on chest X‑ray data across three inter‑hospital shifts show that AURCC closely matches the true model ranking, outperforming simple source‑accuracy baselines especially when source data are limited.
By Juan I\~naki Larrea, Lucas Mansilla, Enzo Ferrante