arXiv:2606. 17710v1 Announce Type: cross Abstract: Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image.
By Mahshad Lotfinia, Sebastian Ziegelmayer, Lisa Adams, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
arXiv:2609.37848v1 Announce Type: cross
Abstract: Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even...
By Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
arXiv:2606. 15910v2 Announce Type: replace Abstract: A vision-language model can answer a question about a chest radiograph or a pathology slide fluently and confidently while barely using the image, relying instead on language priors.
By Reza Khanmohammadi, Kundan Thind, Mohammad M. Ghassemi
arXiv:2604. 08941v2 Announce Type: replace Abstract: Medical Vision-Language Models (VLMs) answering binary presence questions on chest radiographs can fail in two linked ways: they are confidently wrong, and they change answers when a clinically equivalent question is rephrased.
By Binesh Sadanandan, Vahid Behzadan
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
The paper introduces a label‑free method called AURCC for selecting the best foundational model for medical image classification when the target domain lacks labels. AURCC uses a pseudo‑label discrepancy computed by the SUDO framework to score models without fine‑tuning. Experiments on chest X‑ray data across three inter‑hospital shifts show that AURCC closely matches the true model ranking, outperforming simple source‑accuracy baselines especially when source data are limited.
By Juan I\~naki Larrea, Lucas Mansilla, Enzo Ferrante