arXiv AI

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

The paper introduces MSPR-GRE, a multi‑stage phase‑aware self‑supervised reconstruction method for accelerated high‑resolution multi‑echo gradient‑echo MRI. It combines progressive k‑space expansion, phase estimation and refinement, and a relaxation‑informed temporal subspace to reconstruct complex multi‑echo images without fully sampled training data. Evaluation on ex vivo mouse‑brain and in vivo human‑brain datasets shows reduced artifacts, preserved fine anatomy, and improved quantitative maps, especially at higher acceleration factors.

arXiv Computer Vision
Sep 22

MIGA:Shared-Geometry Gaussian Representation with Implicit Amplitude Modeling for Accelerated 3D Multi-Echo MRI

MIGA is a scan‑specific framework for accelerated 3D multi‑echo MRI that uses shared anisotropic Gaussian geometry, a coordinate‑conditioned multi‑output amplitude network, and explicit echo‑specific phase variables. The method jointly optimizes all components from undersampled multi‑coil k‑space data without requiring fully sampled training data. Experiments demonstrate that MIGA outperforms existing methods across various imaging tasks and acceleration factors, especially under stronger undersampling, and offers a favorable quality‑cost balance among full‑volume multi‑echo reconstruction techniques.

By Jingran Xu, Yuanyuan Liu, Yanjie Zhu
arXiv AI
Jul 23

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

arXiv:2607. 20136v1 Announce Type: cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations.

By Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
arXiv AI
Oct 21

MoSAIK: Motion Search with Artificial Intelligence in K-space

MoSAIK (Motion Search with AI in K-space) is a new method that retrospectively estimates in-plane rigid-body motion directly from standard multi-coil TSE k-space data without requiring motion-free references, external navigators, or additional acquisitions. It uses a decoupled convolutional embedding and Transformer encoder to predict rotation and translation parameters, which are then incorporated into a motion-aware reconstruction. In both simulated and in-vivo tests, MoSAIK achieved low estimation errors and improved image quality, reducing visible artefacts while preserving anatomical detail.

By Oscar Dabrowski, Abijith Jagannath, Fr\'ed\'eric Grouiller, S\'ebastien Courvoisier
arXiv Computer Vision
Aug 28

Tissue-Mixture Entropy-Weighted Reconstruction for Partial-Volume-Aware Brain MRI Super-Resolution

The paper introduces AGW-PBR, a brain MRI super‑resolution method that emphasizes tissue‑transition regions affected by the partial‑volume effect. It uses a low‑resolution backbone guided by Sobel edges, soft latent‑basis assignment, and grid‑anchored warping, while training‑time weights are derived from tissue‑mixture entropy computed from registered T1/T2/PD images. Experiments on IXI T2‑weighted scans at 2×, 4×, and 6× show improved full‑image reconstruction and regional fidelity, and the backbone also performs well on fastMRI data without PVE supervision.

By Xiao Tong, Wenyun Yang, Ziheng Zhang, Jingzhi Han, Zhaochu Luo, Jinbo Yang
arXiv Computer Vision
Oct 21

AGGR-Mamba: Mamba-based Network with Attention-Guided Gated Residual Refinement for Undersampled MRI Reconstruction

AGGR-Mamba is a lightweight output‑stage refinement network for undersampled brain MRI reconstruction that builds on a Mamba backbone. The method first generates an initial reconstruction and then applies an Attention Refine Head to recalibrate local anatomical structures, edge textures, and residual‑error regions, followed by a gated residual refinement branch that selectively preserves informative residual features while suppressing redundant responses. Experiments on the IXI brain MRI dataset with T1‑ and T2‑weighted images at acceleration factors R=4 and R=8 show that AGGR‑Mamba achieves competitive PSNR and SSIM performance across different reconstruction settings.

By Yue Zhuo, Wenbin Deng, Lingjun Liu, Xuhang Chen, Zhonghua Xie
arXiv AI
Jun 2

CoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout

arXiv:2606. 00100v1 Announce Type: cross Abstract: Self-supervised deep learning-based methods have shown great promise for accelerated magnetic resonance imaging (MRI) reconstruction, achieving high image quality without requiring fully sampled data for training.

By Tongxi Song, Ziyu Li, Zihan Li, Wen Zhong, Congyu Liao, Yang Yang, Hua Guo, Wenchuan Wu, Qiyuan Tian
arXiv Computer Vision
Oct 22

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

arXiv:2610.24858v2 Announce Type: replace Abstract: Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorte...

By Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus, Fabian Bamberg, Klaus Maier-Hein, Kai Schlamp, Alexander Radbruch, Gianluca Brugnara, Philipp Vollmuth
arXiv AI
Oct 9

SRUG: A Fusion-Driven Generator Network for Medical Image Translation

SRUG is a supervised, fusion‑driven generator network designed for paired MRI sequence synthesis. It eliminates the generator‑discriminator competition by directly learning a deterministic source‑to‑target mapping, using a residual encoder, full‑resolution stem, and a nested multi‑scale decoder to preserve structural fidelity. Experiments on BraTS 2023 and IXI demonstrate competitive reconstruction quality and cross‑dataset transferability, supporting direct supervised generation as a practical approach for medical image translation.

By Xihe Qiu, Yang Dai, Xiaoyu Tan, Sijia Li, Fenghao Sun, Lu Gan, Liang Liu
arXiv Computer Vision
Oct 28

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

The study introduces a physics‑guided, self‑supervised deep learning framework that estimates macromolecular pool fraction (MPF) maps directly from conventional clinical brain MRI sequences (T1‑, T2‑, and FLAIR) without requiring specialized quantitative magnetization transfer scans. By embedding an analytical two‑pool magnetization transfer model and conditioning on acquisition parameters, the method was trained on 7,705 multisite, multivendor MRI sessions and achieved consistent MPF values across vendors and protocols, with a 35.6% reduction in lesions of demyelinating disease compared to normal‑appearing white matter. Cross‑protocol validation in a healthy volunteer showed a mean voxel‑wise absolute difference of 7.7% and a concordance correlation coefficient of 0.888, demonstrating robust cross‑protocol performance.

By Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder, Jan Willem Dankbaar, Stefano Mandija, Alessandro Sbrizzi