arXiv:2601. 11878v2 Announce Type: replace-cross Abstract: To develop a deep-learning method for achieving fast high-resolution MR elastography from highly undersampled data without the need of high-quality training dataset.
By Xi Peng
The paper presents a hybrid approach that combines a convolutional neural network (CNN) with adjoint-based optimization to reconstruct the complex shear modulus in magnetic resonance elastography (MRE). The CNN provides rapid, data-driven initial estimates from displacement measurements, while the adjoint optimization refines these estimates using a physics-based forward model based on a modified stationary Stokes system. Numerical experiments show that the hybrid method converges faster and yields more accurate reconstructions than either technique alone.
By Anwesa Dey, Johann Rudi, Elena Cherkaev
The study explores the feasibility of using a multifrequency neural network, MF‑ElastoNet, originally developed for magnetic resonance elastography, to reconstruct shear‑wave speed maps in ultrasound time‑harmonic elastography (THE). By adapting the MRE pipeline, the authors tested the method on phantom data and in vivo liver scans from 4 healthy volunteers and 14 patients with focal liver lesions, achieving results comparable to the state‑of‑the‑art k‑MDEV method with a negligible mean bias. The work demonstrates that deep learning can be successfully transferred from MRE to THE, potentially improving stiffness mapping in clinical ultrasound elastography.
By H\'elo\"ise Bustin, Tom Meyer, Paul Spiesecke, Jakob Jordan, Anja Hennemuth, Ingolf Sack
arXiv:2610.33124v1 Announce Type: cross
Abstract: 4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resoluti...
By Oliver Welin Odeback, Nerea Gonz\'alez-Aranceta, Sebasti\'an Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, Mia Bonini, David Nordsletten, Patrick Winter, Susanne Schnell, Tobias Granberg, Alexander Fyrdahl, David Marlevi
FlowMoDL is an unrolled neural network designed for highly accelerated 4D flow MRI reconstruction, optimizing both anatomical magnitude and phase-derived velocity accuracy. It alternates a learned (3+1)D spatiotemporal denoiser with conjugate‑gradient data‑consistency updates, using a dual‑pathway conditioning scheme to handle acceleration factors from 10× to 50×. Trained with a deep‑supervision composite loss that penalizes velocity magnitude and angular errors, FlowMoDL outperforms classical and deep‑learning baselines on the multi‑center CMRx4DFlow dataset, achieving superior gradient‑step efficiency and robust convergence across all acceleration factors.
By Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber, Daniel Tenbrinck, Torsten Panholzer, Melanie Schaller, Jana Hutter
The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya
The study introduces a physics‑guided, self‑supervised deep learning framework that estimates macromolecular pool fraction (MPF) maps directly from conventional clinical brain MRI sequences (T1‑, T2‑, and FLAIR) without requiring specialized quantitative magnetization transfer scans. By embedding an analytical two‑pool magnetization transfer model and conditioning on acquisition parameters, the method was trained on 7,705 multisite, multivendor MRI sessions and achieved consistent MPF values across vendors and protocols, with a 35.6% reduction in lesions of demyelinating disease compared to normal‑appearing white matter. Cross‑protocol validation in a healthy volunteer showed a mean voxel‑wise absolute difference of 7.7% and a concordance correlation coefficient of 0.888, demonstrating robust cross‑protocol performance.
By Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder, Jan Willem Dankbaar, Stefano Mandija, Alessandro Sbrizzi
The paper introduces τ+C+Mag, a physics‑driven deep learning method that incorporates auxiliary k‑space magnitude information into accelerated steady‑state dynamic MRI reconstruction. By observing strong consistency of k‑space magnitudes across time‑frames, the authors develop an ADMM‑based unrolling framework with a magnitude‑aware data‑fidelity term, using quadratically smoothed optimization and momentum updates to handle non‑differentiability and non‑convexity. Experiments on retrospectively and prospectively undersampled cine and phase‑contrast flow MRI datasets show improved artifact suppression, sharper anatomical detail, and better phase preservation compared to conventional PD‑DL approaches, as confirmed by blinded expert readers.
By Mahdi Saberi, Ya\c{s}ar Utku Al\c{c}alar, Merve G\"{u}lle, Chetan Shenoy, Mehmet Ak\c{c}akaya
The paper presents a systematic comparison of recurrent neural networks and Transformer models for iterative diffusion MRI tractography, focusing on training strategies, input representations, and hyperparameter tuning. It introduces a generation‑validation phase that provides streamline‑level supervision, enabling the models to achieve the best performance reported on the ISMRM2015 challenge dataset. The study also evaluates the effects of missing bundles, noisy training data, and invalid fibers, and demonstrates applicability to in‑vivo data from the Tractoinferno database.
By Emmanuelle Renauld, Philippe Poulin, Hugo Larochelle, Antoine Th\'eberge, Maxime Descoteaux
The paper introduces CURRENT, a recurrent neural network that simultaneously performs spatial and temporal super‑resolution of 4D flow MRI velocity fields. Trained on synthetic data derived from computational fluid dynamics simulations embedded in real MRI backgrounds, CURRENT outperforms separate spatial or temporal SR models and improves relative pressure estimation. It also generalizes well to in‑vivo acquisitions, offering a unified solution for enhancing 4D flow MRI quality.
By Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
arXiv:2603. 04438v3 Announce Type: replace-cross Abstract: Fully unsupervised deep generative modeling (FU-DGM) offers significant potential for compressively sampled magnetic resonance imaging (CS-MRI) reconstruction.
By Qingyong Zhu, Yumin Tan, Xiang Gu, Dong Liang
arXiv:2508. 05321v4 Announce Type: replace-cross Abstract: Assume you encounter an inverse problem that shall be solved for a large number of data, but no ground-truth data is available.
By Laura Hellwege, Johann Christopher Engster, Moritz Schaar, Thorsten M. Buzug, Maik Stille