arXiv Computer Vision
Sep 22

MIGA:Shared-Geometry Gaussian Representation with Implicit Amplitude Modeling for Accelerated 3D Multi-Echo MRI

MIGA is a scan‑specific framework for accelerated 3D multi‑echo MRI that uses shared anisotropic Gaussian geometry, a coordinate‑conditioned multi‑output amplitude network, and explicit echo‑specific phase variables. The method jointly optimizes all components from undersampled multi‑coil k‑space data without requiring fully sampled training data. Experiments demonstrate that MIGA outperforms existing methods across various imaging tasks and acceleration factors, especially under stronger undersampling, and offers a favorable quality‑cost balance among full‑volume multi‑echo reconstruction techniques.

By Jingran Xu, Yuanyuan Liu, Yanjie Zhu
arXiv AI
Nov 11

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

The paper introduces MSPR-GRE, a multi‑stage phase‑aware self‑supervised reconstruction method for accelerated high‑resolution multi‑echo gradient‑echo MRI. It combines progressive k‑space expansion, phase estimation and refinement, and a relaxation‑informed temporal subspace to reconstruct complex multi‑echo images without fully sampled training data. Evaluation on ex vivo mouse‑brain and in vivo human‑brain datasets shows reduced artifacts, preserved fine anatomy, and improved quantitative maps, especially at higher acceleration factors.

By Juan Liu, Nian Wang
arXiv Computer Vision
Oct 22

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

arXiv:2610.24858v2 Announce Type: replace Abstract: Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorte...

By Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus, Fabian Bamberg, Klaus Maier-Hein, Kai Schlamp, Alexander Radbruch, Gianluca Brugnara, Philipp Vollmuth
arXiv AI
Jul 23

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

arXiv:2607. 20136v1 Announce Type: cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations.

By Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
Hugging Face Trending Papers
Jul 7

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs.