arXiv:2606. 24313v1 Announce Type: new Abstract: AI-driven image-to-image synthesis is rapidly advancing, with growing applications in medical imaging.
By Martin Valls (UFR SFA), Pascal Bourdon (UFR SFA), Christine Fernandez-Maloigne (LabCom I3M), Guillaume Herpe (CHU Poitiers -- Radio, DACTIM-MIS), David Helbert (UFR SFA)
arXiv:2505.05855v4 Announce Type: replace
Abstract: Multi-contrast super-resolution (MCSR) is crucial for enhancing MRI but current deep learning methods are limited. They typically require large, pa...
By Yinzhe Wu, Hongyu Rui, Fanwen Wang, Jiahao Huang, Zhenxuan Zhang, Haosen Zhang, Zi Wang, Guang Yang
arXiv:2603. 03710v3 Announce Type: replace-cross Abstract: Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness.
By Seunghoi Kim, Chen Jin, Henry F. J. Tregidgo, Matteo Figini, Daniel C. Alexander
arXiv:2605.24625v2 Announce Type: replace
Abstract: Ultra-low-field (ULF) MRI offers portable and accessible neuroimaging but suffers from reduced signal-to-noise ratio and limited spatial resolution...
By Toufiq Musah, Salvatore Calcagno, Federica Proietto Salanitri, Xiaomeng Li, Maruf Adewole, Marawan Elbatel
AI-driven image-to-image synthesis is rapidly advancing, with growing applications in medical imaging. Multi-modal image analysis plays a crucial role in optimizing examination quality, yet acquiring multiple imaging modalities in clinical settings remains resource-intensive and time-consuming, especially for 3D imaging.
arXiv:2608.28787v1 Announce Type: new
Abstract: Joint-embedding predictive architectures (JEPAs) have primarily been developed for self-supervised representation learning. Denoising JEPA (D-JEPA) rec...
By Meng Zhou, Wenhao You, Yuxing Chen, Yueying Tian
The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya
arXiv:2606. 17989v1 Announce Type: cross Abstract: Multi-contrast magnetic resonance imaging (MRI) provides complementary information for clinical diagnosis.
By Yonghao Chen, Sicheng Yang, Rui Tang, Lei Zhu
arXiv:2606. 15457v1 Announce Type: cross Abstract: 3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns.
By Weidong Zhang, Yongchan Jung, Shafayat Mowla Anik, Furen Xiao, Vasudevan Janarthanan, Enkhzaya Chuluunbaatar, Byeong Kil Lee, Jeeho Ryoo
arXiv:2602. 18400v3 Announce Type: replace-cross Abstract: Missing data problems, such as missing modalities in multi-modal brain MRI and missing slices in cardiac MRI, pose significant challenges in clinical practice.
By Junkai Liu, Nay Aung, Theodoros N. Arvanitis, Joao A. C. Lima, Steffen E. Petersen, Le Zhang
arXiv:2610.08109v1 Announce Type: new
Abstract: Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while prese...
By Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
The paper introduces a multimodal latent diffusion model that jointly synthesizes volumetric MRI scans and tabular clinical data within a shared latent space using cross‑attention. By fusing the modalities through a variational autoencoder before diffusion, the model reconstructs MRI and tabular data with separate decoders, producing anatomically plausible images that align with synthesized clinical attributes. Evaluation on the German National Cohort dataset shows high‑fidelity image generation and superior tabular performance compared to CTGAN, marking the first demonstration of joint MRI‑tabular modeling in a single diffusion framework.
By Daniel Mensing, Jan Kapar, Jochen G. Hirsch, Matthias G\"unther, Horst Hahn, Marvin N. Wright