arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
arXiv:2508.17299v2 Announce Type: replace
Abstract: Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despi...
By Zhihao Chen, Qi Gao, Zilong Li, Junping Zhang, Yi Zhang, Jun Zhao, Hongming Shan
arXiv:2608. 08919v1 Announce Type: cross Abstract: During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose.
By Alzahra Altalib, Chunhui Li, Christopher Hamill Taylor, Sankar Pillai, Alessandro Perelli
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
arXiv:2605.20470v2 Announce Type: replace-cross
Abstract: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noi...
By Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat, Khaled Z. Alawneh, Ahmad Awad Qandeel, Alessandro Perelli
The paper introduces Conditional Diffusion Posterior Alignment (CDPA), a method that scales diffusion-based sparse‑view CT reconstruction to large 3D volumes by conditioning a 2D U‑Net diffusion model on an initial 3D reconstruction and enforcing data‑consistency alignment. CDPA addresses high memory demands, limited 3D training data, and slice‑wise inconsistencies, achieving state‑of‑the‑art performance on synthetic and real Cone Beam CT data. The authors also demonstrate that the same approach improves fast denoising U‑Nets, delivering near‑diffusion quality at a fraction of the computational cost.
By Luis Barba, Johannes Kirschner, Benjamin Bejar
The paper introduces a physics‑driven, cross‑domain iterative framework for self‑supervised low‑dose CT denoising. It first uses a learned sinogram prior and the LDCT noise model to separate Poisson and Gaussian noise components, then applies binomial and Gaussian data thinning to create two training pairs with independent noise realizations. These pairs train an image‑domain network whose outputs are forward‑projected to refine the prior, yielding consistent performance gains over existing self‑supervised baselines and comparable results to supervised methods.
By Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.
By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu
arXiv:2603. 00205v2 Announce Type: replace-cross Abstract: Generative models, particularly Diffusion Models (DM), have shown strong potential for Computed Tomography (CT) reconstruction serving as expressive priors for solving ill-posed inverse problems.
By Jiayang Shi, Lincen Yang, Zhong Li, Tristan van Leeuwen, Daniel M. Pelt, K. Joost Batenburg
arXiv:2602. 23214v2 Announce Type: replace-cross Abstract: Plug-and-Play diffusion prior (PnPDP) frameworks have emerged as a powerful paradigm for solving imaging inverse problems by treating pretrained generative models as modular priors.
By Chenhe Du, Xuanyu Tian, Qing Wu, Muyu Liu, Jingyi Yu, Hongjiang Wei, Yuyao Zhang