arXiv AI

Deep denoising autoencoder-based non-invasive blood flow detection for arteriovenous fistula

The paper presents a deep denoising autoencoder (DAE) approach for non‑invasive detection of blood flow in arteriovenous fistulas (AVFs) using waveform data processed by a one‑level discrete wavelet transform. The DAE performs dimensionality reduction and reconstruction, producing a latent representation that achieves 93% accuracy in detecting AVF dysfunction and 92% accuracy in identifying patient‑specific characteristics. Lightweight versions of the model can maintain performance on less powerful devices, indicating practical applicability for routine AVF monitoring.

arXiv Machine Learning
Nov 2

Variational decomposition autoencoding improves disentanglement of latent representations

The paper introduces variational decomposition autoencoding (VDA), a framework that biases signal decomposition into latent representations. VDA is realized as variational decomposition autoencoders (DecVAEs), encoder-only networks that learn multiple latent subspaces aligned with time‑frequency characteristics. Experiments on simulated data and three speech datasets show that DecVAEs outperform traditional VAEs in disentanglement quality and robustness, producing factor‑specific latent subspaces when generative factors have distinct spectral signatures.

By Ioannis N. Ziogas, Aamna Al Shehhi, Ahsan H. Khandoker, Leontios J. Hadjileontiadis
arXiv Machine Learning
Aug 20

Atrial Fibrillation Detection with Arbitrary Leads via a Codebook-Based Reconstruction-Classification Framework

The paper introduces DCGCNet, a dual-codebook graph collaborative network that jointly reconstructs ECG signals and classifies atrial fibrillation. It incorporates a local‑global contrastive module for noise‑invariant feature learning and an adaptive codebook vector quantizer to prevent codebook collapse. The model achieves state‑of‑the‑art intra‑dataset performance and consistently attains AUC > 0.98 across seven cross‑dataset settings, even under realistic noisy conditions.

By Hongtao Li, Jia Wei, Guoyao Li, Yuchen Lei, Guangnian Ma, Jia Xiao, Yuanjun Lai, Shuzhen Lv, Xueqiang Ouyang
arXiv AI
Sep 18

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.

By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu
arXiv AI
Sep 7

Attention-guided super-resolution of 4D flow MRI in carotid arteries

The paper presents a deep learning super‑resolution framework for 4D flow MRI of carotid arteries, using convolutional block attention modules to focus on clinically relevant spatial features and reduce noise. Trained on 120 patients with 240 stenosed carotid arteries, the model leverages patient‑specific CFD simulations as high‑resolution ground truth. Results show a significant reduction in RMSE and improved reconstruction of complex flow patterns compared to a baseline without attention.

By Ali Mokhtari, Dominik Obrist
arXiv Computer Vision
Oct 21

Vascular anatomy-aware self-supervised pre-training for X-ray angiogram analysis

The paper introduces VasoMIM, a vascular anatomy‑aware masked image modeling framework for X‑ray angiogram analysis, which uses an anatomy‑guided masking strategy and an anatomical consistency loss to learn robust vascular representations. It also presents XA‑170K, the largest pre‑training dataset for X‑ray angiograms. Experiments on six datasets and four downstream tasks show that VasoMIM outperforms existing methods and achieves state‑of‑the‑art performance.

By De-Xing Huang, Chaohui Yu, Xiao-Hu Zhou, Tian-Yu Xiang, Qin-Yi Zhang, Mei-Jiang Gui, Rui-Ze Ma, Chen-Yu Wang, Nu-Fang Xiao, Fan Wang, Zeng-Guang Hou
arXiv Computer Vision
Nov 16

PADSNet: Physics-Aware Dual-Stream Network with Biomechanical Priors for Laryngeal Lesion Classification

PADSNet is a Physics-Aware Dual-Stream Network that classifies laryngeal lesions by combining visual features with biomechanical reasoning. It uses a Wavelet-Attention Enhancement Module to merge spatial texture and dynamic frequency representations, and a Knowledge Computing Module to extract interpretable biomechanical indices from glottal distance waveforms. These indices are fed into a Physics-Aware Gating Module to recalibrate visual features, achieving an accuracy of 0.8452, F1-score of 0.8090, sensitivity of 0.7953, and specificity of 0.8866 on a clinical dataset.

By Zhenzhen You, Weifeng Yu, Zhenghao Shi, Shuangli Du, Minghua Zhao, Yingcheng Zhao, Xinhong Hei, Demin Kong, Xiaoyong Ren, Jin Hou
arXiv Machine Learning
Nov 11

Deviation-Aware Pretraining for Cardiovascular Disease Detection from Electrocardiograms

The paper introduces a self‑supervised ECG feature extraction framework trained on nearly one million unlabeled 12‑lead recordings. It comprises Deviation Localization Embedding, which identifies waveform deviations, and Association Reconstruction Embedding, which captures cross‑lead abnormal patterns. The approach yields up to 6.5% AUROC and 12.8% F1 gains on public datasets without fine‑tuning, and visualizations show meaningful disease grouping and anomaly detection.

By Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li
arXiv AI
Sep 21

BEAT-Net: Injecting Biomimetic Spatio-Temporal Priors for Interpretable ECG Diagnosis

BEAT-Net is a supervised biomimetic framework for ECG diagnosis that incorporates QRS-centered tokenization and a hierarchical architecture mirroring a cardiologist’s workflow. It processes heartbeat sequences through morphological, spatial, temporal, and transformer-based stages, achieving an AUC of 0.924 on large benchmarks while using only 0.7 million parameters. The model outperforms the 39.5‑million‑parameter HeartLang foundation model on morphological form classification and demonstrates superior cross‑dataset generalization with only 35% of the training data.

By Runze Ma, Haonan Lyu, Shunbo Jia, Qiang Yang, Muzi Xu, Jiaqi Zhang, Zihe Luo, Caizhi Liao
arXiv Machine Learning
Aug 28

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

The paper introduces Graph-CMMC, a graph-based pseudo‑multimodal contrastive learning framework for 12‑lead ECG representations. It transforms ECG waveforms into Gramian Angular Difference Field (GADF) images to create complementary views, then aligns these views while modeling inter‑lead dependencies with a graph module. Experiments on coronary artery occlusion classification show that Graph-CMMC performs competitively with supervised methods, highlighting the value of GADF representations and explicit graph modeling for robust ECG analysis.

By Mengyu Wang, Kozo Okada, Takafumi Goto, Natsuko Jinba, Hiroki Yamaya, Kiyoshi Hibi, Tomoki Hamagami