The paper introduces a ptychography‑supervised learning framework that transforms 4D‑STEM data into real‑time atomic‑resolution phase images. By training a compact model on physics‑constrained reference phase maps from a single AuPd dataset, the method predicts local phase patches directly from diffraction patterns without probe calibration or iterative optimization. The resulting workflow achieves an online latency of ~0.27 ms per probe position, a 1,000‑fold speed‑up over GPU‑accelerated ePIE, and maintains atomic‑scale lattice contrast while generalizing across materials, defocus conditions, and instruments.
By H. Yue, C. -C. Chen, C. -N. Hsiao, J. Cheng, Y. Liu, X. Z. Liao, Steve F. Shu
arXiv:2606. 10547v1 Announce Type: cross Abstract: Energy Dispersive X-ray (EDX) tomography in Scanning Transmission Electron Microscopy (STEM) enables 3D compositional and elemental mapping at the nanoscale, but its use is limited by restricted tilt ranges and low-dose conditions required to avoid beam damage.
By Daniel del Pozo Bueno, Serge Brosset, Theo Monniez, Gabriele Navarro, Philippe Ciuciu, Zineb Saghi
arXiv:2607. 13107v1 Announce Type: cross Abstract: The experimental reconstruction of the 3D two-photon momentum density (TPMD) via angular correlation of electron-positron annihilation radiation (ACAR) is a particularly useful method for studying material Fermi surfaces.
By Georg F. B. Lovric, Bryn Drury, Carola-Bibiane Sch\"onlieb, Stephen B. Dugdale, Ander Biguri
arXiv:2606. 31332v1 Announce Type: new Abstract: Protein automodeling from cryo-EM density maps faces unique challenges in enforcing physicochemical validity and managing conformational heterogeneity.
By Minzhang Li, Mingrui Li, Weichen Qin, Qihe Chen, Sixian Shen, Yuan Pei, Jiakai Zhang, Jingyi Yu
4D‑TEMPO is a differentiable physical renderer that directly fits atomic positions, microscope settings, and detector response to 4D‑STEM electron counts using a Poisson likelihood. It outputs each atom as a Gaussian primitive with a 3‑D position, thermal width, and a per‑atom uncertainty derived from Fisher information, which also informs dose requirements and separates calibration from imaging. On simulated and experimental WSe₂ data, 4D‑TEMPO reduces in‑plane and depth errors compared to existing methods, predicts held‑out patterns more accurately, and achieves rapid reconstruction times, enabling low‑dose, real‑time 3‑D imaging of beam‑sensitive materials.
By Ramani Duraiswami, Yichao Zhang
The paper introduces Scalable Bayesian Optimization of Composite Functions (SBOCF) for efficiently estimating physical parameters from scientific images, specifically targeting electron microscopy PACBED patterns. SBOCF leverages the composite structure of the image-matching objective, reducing modeled outputs from 24,649 to 11 by using patch-level summaries and correction terms. With only 50 simulator evaluations, SBOCF outperformed standard Bayesian optimization, achieving up to 290× lower median SSE on synthetic SrTiO3 benchmarks and producing accurate parameter estimates on experimental data without task-specific pretraining.
By Dasol Yoon, Poompol Buathong, Chia-Hao Lee, Yujia Zhang, David A. Muller, Peter I. Frazier
arXiv:2510. 16165v2 Announce Type: replace Abstract: A key question in benchmarking generative crystal reconstruction models is how the amount and type of crystallographic information provided to a generative model affects its ability to reconstruct atomic structures.
By Charles Rhys Campbell, Aldo H. Romero, Kamal Choudhary
The paper introduces the All-Atom Diffusion Tokenizer (ADT), a method that assigns one token per atom for small molecules and one token per protein residue that captures both backbone and side‑chain geometry. ADT separates token granularity from reconstruction resolution, using diffusion models to recover detailed atomic positions from the compact tokens. Experiments show that ADT can reconstruct structures accurately while enabling high‑quality autoregressive generation of both small molecules and all‑atom protein structures.
By Xuantuo Huang, Encheng Su, Aoran Wang, Pan Tan, Shengyong Xu, Yizhou Wang, Chen Tang, Shixiang Tang, Mingxiao Li
arXiv:2505. 12650v2 Announce Type: replace-cross Abstract: Reconstructing atomistic crystal structures from a single noisy STEM projection is an ill-posed inverse problem: multiple lattices can explain similar contrast, and purely feed-forward models cannot verify physical validity.
By Yaotian Yang, Yiwen Tang, Yizhe Chen, Xiao Chen, Jiangjie Qiu, Hao Xiong, Haoyu Yin, Zhiyao Luo, Yifei Zhang, Sijia Tao, Wentao Li, Qinghua Zhang, Yuqiang Li, Wanli Ouyang, Bin Zhao, Xiaonan Wang, Fei Wei
arXiv:2609.10376v1 Announce Type: new
Abstract: Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is...
By Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Fr\'ed\'eric Lavoie, Herve Lombaert
The paper introduces a spatial-frequency learning framework for enhancing Scanning Transmission Electron Microscopy (STEM) images. It employs a spatial-frequency fusion network that separately enhances features in the spatial and frequency domains before fusing them, leveraging periodic atomic arrangements in the frequency domain and local atomic details in the spatial domain. Additionally, the authors present a STEM noise calibration method to synthesize realistic images, creating a diverse dataset that improves performance on synthetic and real advanced material images, including better atomic localization accuracy.
By Hesong Li, Ying Fu, Ziqi Wu, Ruiwen Shao, Tao Zhang
Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatt...