arXiv:2610.13357v5 Announce Type: replace-cross
Abstract: Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, leaving patient metad...
By Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
ECGGuard is a deep watermarking framework that embeds metadata into single‑lead ECG signals without quantizing the waveform. It uses a fully convolutional generator, a detector that decodes frame‑by‑frame, and a frozen arrhythmia classifier during training to prevent diagnostic changes. The system achieves over 98% bit accuracy under time shifts and recovers a 16‑bit payload exactly in 99.95% of clean segments, with robust performance under deletions, packet loss, and unseen subjects.
By Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.
By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
The study investigates how different tokenization methods affect ECG Transformer models by comparing eight strategies across four backbone architectures on the CPSC2018 classification task. Physiology-aware tokenizations such as Median-beat and HeartLang achieve higher mean macro-AUCs (0.893 and 0.889) than point-wise and patch-wise approaches (0.822 and 0.824), while also reducing sequence length and training memory usage. Combining the two physiology-aware representations further improves macro-AUC by 8.2%.
By Jiawei Li, Fabio Bonassi, Johan Sundstr\"om, Thomas B. Sch\"on, Ant\^onio H. Ribeiro
ECGQuest is a new benchmark that evaluates language models on the contextual knowledge required for electrocardiogram interpretation, featuring 10,904 True/False questions derived from 23 ECG references and 2003‑2025 Computing in Cardiology proceedings. The study tested 23 commercial and open‑source models, finding that zero‑shot accuracy ranged from 49.5% to 74.4% and that fine‑tuning with Low‑Rank Adaptation improved all open‑source models by 6.5–14.1%, with the best fine‑tuned model achieving 76.3% accuracy and a five‑model ensemble reaching 78.5%. ECGQuest demonstrates that parameter‑efficient fine‑tuning can enable smaller models to compete with larger commercial ones on ECG‑specific tasks.
By Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
The paper introduces CARMEN, a foundation model trained on ten cardiorespiratory waveforms without labels, covering 2.27 million modality-hours. It can process any subset of the signals from 10 s to 5 min and uses a conditioning mechanism called LSCNorm to restore absolute signal levels, improving performance on tasks such as intraoperative hypotension detection. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on most tasks and surpassed other foundation models, maintaining robustness even when some channels are missing.
By Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun, Hyung-Chul Lee
GeoRVQ introduces a coarse‑to‑fine masked token model that incorporates decoder‑induced geometry into residual‑vector‑quantized physiological waveforms. By using geometry‑aware soft targets and expected distortion, the model improves exact token accuracy from 0.133 to 0.143, reduces decoded distance from 0.606 to 0.393, and raises R‑peak F1 from 0.784 to 0.837 on datasets such as MIMIC‑IV Waveform, VitalDB, and CODE‑15%. The approach demonstrates that decoder‑aware objectives can enhance waveform and event preservation without a large increase in token accuracy.
By Bo Cui, Yaowen Zhang
The paper demonstrates that large language models (LLMs) used to preliminarily assess medical device documentation can produce inconsistent results across different commercial deployments and settings. By constructing a fully deterministic pipeline—including OCR, chunking, embedding, indexing, retrieval, and inference—the authors achieved byte‑identical outputs across repeated runs, varied machines, and even interruptions. The study shows that end‑to‑end determinism is possible and provides a verifiable foundation for audit and change control in regulatory compliance.
By Ryosuke Suzuki
arXiv:2610.13357v3 Announce Type: replace-cross
Abstract: Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, making patient metada...
By Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
BiMa-ECGSR reconstructs a full 12‑lead ECG from reduced lead sets using a bidirectional Mamba state‑space encoder–decoder, offering both regression (BiMa‑SR) and diffusion (DiBiMa‑SR) variants. Trained on PTB‑XL, the models achieve high Pearson correlations—up to 0.979 for I+II+V1+V4—outperforming a least‑squares linear filter across 18 configuration–cohort pairs. A 12‑lead classifier trained on real ECGs attains macro AUROC scores within 0.004 of real ECGs when using reconstructions from three or four leads, and the model processes a 10‑second record in 45.8 ms on a GPU.
By Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi
arXiv:2608. 12695v1 Announce Type: new Abstract: Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences.
By Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
BEAT-Net is a supervised biomimetic framework for ECG diagnosis that incorporates QRS-centered tokenization and a hierarchical architecture mirroring a cardiologist’s workflow. It processes heartbeat sequences through morphological, spatial, temporal, and transformer-based stages, achieving an AUC of 0.924 on large benchmarks while using only 0.7 million parameters. The model outperforms the 39.5‑million‑parameter HeartLang foundation model on morphological form classification and demonstrates superior cross‑dataset generalization with only 35% of the training data.
By Runze Ma, Haonan Lyu, Shunbo Jia, Qiang Yang, Muzi Xu, Jiaqi Zhang, Zihe Luo, Caizhi Liao