The paper introduces TF‑IG, a compact two‑branch model that learns heart‑rate from photoplethysmography by combining temporal pulse morphology and frequency‑domain periodicity. A novel interaction‑gated fusion module explicitly models agreement and discrepancy between the two domains, while a shared regression head maps the fused features to HR predictions. On the BIDMC PPG dataset, TF‑IG achieves a mean absolute error of 1.227 BPM and 92.28 % of estimates within 3 BPM using only 84.6 K parameters.
By Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
BeatFlow-ECG is a conditional rectified‑flow model that reconstructs single‑channel ECG signals from synchronized photoplethysmography (PPG) and inertial measurement unit (IMU) data. The architecture uses a convolutional encoder‑decoder with a transformer bottleneck and explicit flow‑time conditioning, incorporating motion information through IMU‑derived features, motion‑dependent loss weighting, and a curriculum learning strategy. Evaluated on PPG‑DaLiA and WESAD datasets with leave‑one‑subject‑out protocols, BeatFlow‑ECG outperforms deterministic, adversarial, and diffusion‑based baselines, achieving Pearson correlations of 0.983–0.986 and R‑peak F1 scores of 0.946–0.955, while reducing L1 error compared to Conditional DDPM‑1D.
By Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about...
Remote Photoplethysmography (rPPG) enables contactless pulse estimation from facial videos, serving as a vital tool for health monitoring. However, current deep learning methods often struggle under complex disturbances, particularly varying illumination, facial expressions, and unconstrained head movements.
The paper introduces DPNet, a Mamba-based deep learning framework for denoising photoplethysmography (PPG) signals while preserving physiological information. It incorporates a scale‑invariant signal‑to‑distortion ratio loss and an auxiliary heart‑rate predictor to enhance waveform fidelity and maintain heart‑rate accuracy. Experiments on the BIDMC dataset show that DPNet outperforms conventional filtering and existing neural models in robustness against synthetic noise and real‑world motion artifacts, making it suitable for wearable healthcare systems.
By I Chiu, Yu-Tung Liu, Kuan-Chen Wang, Hung-Yu Wei, Yu Tsao
CardioFusion-AI is a framework for robust fusion of ECG and PPG signals in wearable physiological monitoring. Its signal‑processing front end, featuring R‑peak and systolic‑peak detection, an Orphanidou‑type signal‑quality index, and beat‑by‑beat pulse transit time estimation, was validated on 53 intensive‑care recordings and a fetal ECG database. In a controlled synthetic degradation study, attention fusion achieved the lowest overall error, while adaptive gates reallocated weight toward the healthy modality under complete loss, and signal‑quality conditioning improved performance when PPG was missing.
By Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
arXiv:2610.33788v1 Announce Type: new
Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. However, existing approaches to universal...
By Huaming Du, Zhixian Xie, Gaoyang Zhen, Gang Kou, Guisong Liu, Yanchao Tan, Wendan Tao, Yuhao Xu, Carl Yang
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fus...
VideoPulse is a neonatal dataset and end‑to‑end pipeline that estimates heart rate and peripheral capillary oxygen saturation (SpO2) from facial video without contact. The dataset contains 157 recordings from 52 neonates, and the pipeline uses face alignment, artifact‑aware supervision, and 3D CNN backbones to produce predictions every 2 seconds. On the NBHR dataset the model achieves a heart‑rate MAE of 2.97 bpm and SpO2 MAE of 1.69 %.
"whyItMatters":"The results show that short, unaligned neonatal video segments can accurately estimate vital signs, offering a low‑cost, non‑invasive monitoring option for neonatal intensive care."
By Deependra Dewagiri, Kamesh Anuradha, Pabadhi Liyanage, Helitha Kulatunga, Pamuditha Somarathne, Udaya S. K. P. Miriya Thanthrige, Nishani Lucas, Anusha Withana, Joshua P. Kulasingham
The study examined how well physiological properties from contact photoplethysmography (PPG) can be recovered by camera-based remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while heart‑rate estimates showed modest accuracy, other dynamic measures such as autocorrelation, spectral content, and Lyapunov exponents largely failed to preserve recording‑specific characteristics. They also observed that lighting and motion influence endpoint accuracy, yet these factors did not explain the lack of dynamical correspondence.
By Timothy Oladunni, Farouk Ganiyu-Adewumi