Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fus...
BeatFlow-ECG is a conditional rectified‑flow model that reconstructs single‑channel ECG signals from synchronized photoplethysmography (PPG) and inertial measurement unit (IMU) data. The architecture uses a convolutional encoder‑decoder with a transformer bottleneck and explicit flow‑time conditioning, incorporating motion information through IMU‑derived features, motion‑dependent loss weighting, and a curriculum learning strategy. Evaluated on PPG‑DaLiA and WESAD datasets with leave‑one‑subject‑out protocols, BeatFlow‑ECG outperforms deterministic, adversarial, and diffusion‑based baselines, achieving Pearson correlations of 0.983–0.986 and R‑peak F1 scores of 0.946–0.955, while reducing L1 error compared to Conditional DDPM‑1D.
By Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about...
arXiv:2608. 07759v1 Announce Type: cross Abstract: Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration.
By Farouk Ganiyu Adewumi, Timothy Oladunni, Rochak Ghimire, Kosisochukwu Ogbuanya, Sanaa Reeves, Sandy Akoy
arXiv:2607. 27076v1 Announce Type: new Abstract: Continuous cuffless blood pressure (BP) monitoring remains challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditions.
By Kindeep K. Dhatt, Tengyue Wu, Hanbang Hua, Yayun Du
ARTA is a graph‑based combinatorial framework that improves interbeat interval estimation from wearable ECG by integrating candidates from multiple detectors into a directed acyclic graph. It uses detector agreement, ECG quality, and history‑dependent transition costs to select a coherent heartbeat sequence via beam‑search dynamic programming, effectively suppressing false detections and recovering missed beats. On benchmark datasets, ARTA reduces heart‑rate mean absolute error by 54% compared to the best single detector and achieves high accuracy in R‑peak detection and IBI estimation while remaining lightweight and training‑free.
By Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
arXiv:2509.19774v3 Announce Type: replace-cross
Abstract: Electrocardiography (ECG) is the clinical gold standard for cardiovascular disease (CVD) assessment, yet continuous monitoring is constrained...
By Xiaocheng Fang, Jiarui Jin, Haoyu Wang, Che Liu, Jieyi Cai, Yujie Xiao, Guangkun Nie, Bo Liu, Shun Huang, Hongyan Li, Shenda Hong
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
The study evaluates how acquisition context and photoplethysmography (PPG) signals contribute to session‑calibrated blood pressure tracking using a wearable‑state model on 653 AuroraBP participants. Adding contextual information reduced mean absolute errors (MAEs) for systolic and diastolic BP by 0.436 mmHg and 0.126 mmHg, respectively, while PPG alone provided modest improvements. Exploratory follow‑ups with sensor‑history ensembles and pulse‑rate fusion yielded only slight gains, and a separate intraoperative model (VitalDB) showed limited PPG benefit.
By Farouk Ganiyu Adewumi, Timothy Oladunni
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
The study examined how well physiological properties from contact photoplethysmography (PPG) can be recovered by camera-based remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while heart‑rate estimates showed modest accuracy, other dynamic measures such as autocorrelation, spectral content, and Lyapunov exponents largely failed to preserve recording‑specific characteristics. They also observed that lighting and motion influence endpoint accuracy, yet these factors did not explain the lack of dynamical correspondence.
By Timothy Oladunni, Farouk Ganiyu-Adewumi
The study examined how well specific physiological properties of contact photoplethysmography (PPG) can be recovered when converted to camera-derived remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while overall heart‑rate accuracy was modest, many dynamic properties (e.g., autocorrelation, spectral measures, Lyapunov exponents) showed little recording‑specific correspondence, and differences varied with skin tone and observation conditions. The results demonstrate that preserving individual recording characteristics depends on the property and conditions, and population‑level agreement does not guarantee individual‑level fidelity.