arXiv:2607. 05230v1 Announce Type: new Abstract: Pre-term infants are susceptible to potentially harmful apnoea-related cessations of breathing due to immature respiratory control.
By Dineo Serame, Lionel Tarassenko, Mauricio Villarroel
Pre-term infants are susceptible to potentially harmful apnoea-related cessations of breathing due to immature respiratory control. However, reliable respiratory monitoring in the neonatal intensive care unit (NICU) remains challenging because motion artefacts, sensor displacement, and skin fragility can compromise contact-based measurements.
The paper introduces Heartian, a physiology‑aware framework that augments Gaussian head avatars with cardiac‑cycle‑dependent albedo modulation, enabling the encoding of remote photoplethysmography (rPPG) signals. By supervising with synchronized contact PPG, the method models the cardiac waveform as a sum of two Gaussians and learns per‑frame spatial residuals via a lightweight MLP. Experiments on 152 stationary recordings from UBFC‑rPPG, PURE, and MMPD show heart‑rate estimation errors as low as 0.29 bpm MAE and 0.38 % MAPE, while preserving reconstruction quality with negligible PSNR loss.
By Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Ak\c{s}it
Remote Photoplethysmography (rPPG) enables contactless pulse estimation from facial videos, serving as a vital tool for health monitoring. However, current deep learning methods often struggle under complex disturbances, particularly varying illumination, facial expressions, and unconstrained head movements.
Remote photoplethysmography (rPPG) estimates the blood volume pulse (BVP) signal from facial videos, enabling contact-free health monitoring. Conventional clip-wise approaches, which use video clips as input, require capturing over one hundred frames before inference, thus introducing several seconds of delay and hindering real-time use.
arXiv:2607. 06598v1 Announce Type: cross Abstract: Heart rate measurement is one of the key requirements for real-time health monitoring, in particular for health caring of elderly people.
By Kelly Li, Fulu Li
Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose $\unicode{x1F493}$Heartian, a physiology-aware...
The study examined how well physiological properties from contact photoplethysmography (PPG) can be recovered by camera-based remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while heart‑rate estimates showed modest accuracy, other dynamic measures such as autocorrelation, spectral content, and Lyapunov exponents largely failed to preserve recording‑specific characteristics. They also observed that lighting and motion influence endpoint accuracy, yet these factors did not explain the lack of dynamical correspondence.
By Timothy Oladunni, Farouk Ganiyu-Adewumi
The study examined how well specific physiological properties of contact photoplethysmography (PPG) can be recovered when converted to camera-derived remote photoplethysmography (rPPG) across 655 recordings. Using the CHROM method, the authors found that while overall heart‑rate accuracy was modest, many dynamic properties (e.g., autocorrelation, spectral measures, Lyapunov exponents) showed little recording‑specific correspondence, and differences varied with skin tone and observation conditions. The results demonstrate that preserving individual recording characteristics depends on the property and conditions, and population‑level agreement does not guarantee individual‑level fidelity.
arXiv:2606. 12378v1 Announce Type: cross Abstract: Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments.
By Zhi Wei Xu, Torbj\"orn E. M. Nordling
Apnoea of prematurity is characterised by recurrent episodes of cessation of breathing and remains difficult to detect reliably using routinely monitored physiological signals in the Neonatal Intensive Care Unit (NICU). Existing bedside monitors rely primarily on respiratory rate and oxygen saturation thresholds, often generating high false-positive alarm rates and missing short or irregular events.
arXiv:2607. 07996v1 Announce Type: cross Abstract: Continuous oxygen saturation (SpO$_2$) estimation from wearable photoplethysmography (PPG) is important for long-term health monitoring, but low-quality red and infrared PPG segments can distort waveform morphology and degrade SpO$_2$ prediction accuracy.
By Zequan Liang, Elahe Hosseini, Ning Miao, Mahdi Pirayesh Shirazi Nejad, Wei Shao, Ehsan Kourkchi, Setareh Rafatirad, Houman Homayoun