arXiv:2606. 07365v1 Announce Type: cross Abstract: Photoplethysmography (PPG), a non-invasive measure of changes in blood volume, is widely used in both wearable devices and clinical settings.
By Eloy Geenjaar, Vince Calhoun, Scott Daly, Gouthaman KV, Lie Lu, Trisha Mittal, Daniel P. Darcy
arXiv:2608. 00943v1 Announce Type: cross Abstract: Automated sleep staging assigns discrete stage labels to successive time epochs throughout an overnight recording; conventionally each window spans at least 30 seconds, reflecting the minimum temporal resolution of the clinical scoring standard.
By Shuntian Zheng, Jiawei Wang, Cong Fu, Huan Yu, Chen Chen, Yu Guan, Sai Gu
arXiv:2606. 15284v1 Announce Type: cross Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support.
By Chenyang He, Xinyi Shao, Shun Huang, Bosong Huang, Daoqiang Zhang, Ming Jing, Cheng Ding
The Cross-View Attention Fusion Network (CVAF‑Net) is a dual‑view deep learning model that estimates cardiac output from short photoplethysmography (PPG) segments by combining raw PPG signals with a structured prior‑guided feature sequence map through cross‑view attention. Evaluated on simulated, vasoconstriction, and real‑world activity datasets, CVAF‑Net achieved a mean absolute error of 0.19 L/min on simulated data and as low as 1.20 L/min in real settings, outperforming most benchmarks while reducing computational cost by twelvefold compared to a leading Transformer model. Plausibility checks confirmed physiologically consistent correlations with age, heart rate, and systemic vascular resistance.
By Yaowen Zhang, Bo Cui, Libera Fresiello, Peter H. Veltink, Dirk W. Donker, Ying Wang
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
arXiv:2608. 14656v1 Announce Type: cross Abstract: Photoplethysmography (PPG) is widely used in consumer wearables because of its low cost and ease of acquisition.
By Zhongli Wu, Zhuangzhi Gao, He Zhao, Feixiang Zhou, Fu Wang, Jinru Ding, Yuankai Wang, Hongyi Qin, Gregory Y. H. Lip, Bil Kirmani, Yalin Zheng
arXiv:2608. 01820v1 Announce Type: cross Abstract: Non-invasive blood glucose level (BGL) estimation from photoplethysmography (PPG) holds great promise for wearable health monitoring, but results across studies are hard to compare due to inconsistent datasets, data leakage, and non-standardized evaluation metrics.
By Supraja Ramesh, Markus Neufeld, Michael K\"uttner, Tobias R\"oddiger, Michael Beigl
arXiv:2608. 07759v1 Announce Type: cross Abstract: Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration.
By Farouk Ganiyu Adewumi, Timothy Oladunni, Rochak Ghimire, Kosisochukwu Ogbuanya, Sanaa Reeves, Sandy Akoy
BeatFlow-ECG is a conditional rectified‑flow model that reconstructs single‑channel ECG signals from synchronized photoplethysmography (PPG) and inertial measurement unit (IMU) data. The architecture uses a convolutional encoder‑decoder with a transformer bottleneck and explicit flow‑time conditioning, incorporating motion information through IMU‑derived features, motion‑dependent loss weighting, and a curriculum learning strategy. Evaluated on PPG‑DaLiA and WESAD datasets with leave‑one‑subject‑out protocols, BeatFlow‑ECG outperforms deterministic, adversarial, and diffusion‑based baselines, achieving Pearson correlations of 0.983–0.986 and R‑peak F1 scores of 0.946–0.955, while reducing L1 error compared to Conditional DDPM‑1D.
By Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about...
arXiv:2606. 10410v1 Announce Type: new Abstract: Objective: Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data.
By Davood Fattahi, Runze Yan, Saurabh Kataria, Zhaoliang Chen, Xiao Hu
Non-invasive blood glucose level (BGL) estimation from photoplethysmography (PPG) holds great promise for wearable health monitoring, but results across studies are hard to compare due to inconsistent datasets, data leakage, and non-standardized evaluation metrics. We present the first reproducible, extensible evaluation pipeline and use it to reassess five representative PPG-based BGL methods on published datasets under three increasingly strict data-split protocols: random window-level, participant-aware, and leave-some-participants-out (LSPO).