Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure.
Remote Photoplethysmography (rPPG) enables contactless pulse estimation from facial videos, serving as a vital tool for health monitoring. However, current deep learning methods often struggle under complex disturbances, particularly varying illumination, facial expressions, and unconstrained head movements.
arXiv:2606. 30156v1 Announce Type: cross Abstract: Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics.
By Nouhaila Fraihi, Ouassim Karrakchou, Mounir Ghogho
Remote photoplethysmography (rPPG) estimates the blood volume pulse (BVP) signal from facial videos, enabling contact-free health monitoring. Conventional clip-wise approaches, which use video clips as input, require capturing over one hundred frames before inference, thus introducing several seconds of delay and hindering real-time use.
Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about...
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
arXiv:2606. 07365v1 Announce Type: cross Abstract: Photoplethysmography (PPG), a non-invasive measure of changes in blood volume, is widely used in both wearable devices and clinical settings.
By Eloy Geenjaar, Vince Calhoun, Scott Daly, Gouthaman KV, Lie Lu, Trisha Mittal, Daniel P. Darcy
The paper introduces TF‑IG, a compact two‑branch model that learns heart‑rate from photoplethysmography by combining temporal pulse morphology and frequency‑domain periodicity. A novel interaction‑gated fusion module explicitly models agreement and discrepancy between the two domains, while a shared regression head maps the fused features to HR predictions. On the BIDMC PPG dataset, TF‑IG achieves a mean absolute error of 1.227 BPM and 92.28 % of estimates within 3 BPM using only 84.6 K parameters.
By Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
BeatFlow-ECG is a conditional rectified‑flow model that reconstructs single‑channel ECG signals from synchronized photoplethysmography (PPG) and inertial measurement unit (IMU) data. The architecture uses a convolutional encoder‑decoder with a transformer bottleneck and explicit flow‑time conditioning, incorporating motion information through IMU‑derived features, motion‑dependent loss weighting, and a curriculum learning strategy. Evaluated on PPG‑DaLiA and WESAD datasets with leave‑one‑subject‑out protocols, BeatFlow‑ECG outperforms deterministic, adversarial, and diffusion‑based baselines, achieving Pearson correlations of 0.983–0.986 and R‑peak F1 scores of 0.946–0.955, while reducing L1 error compared to Conditional DDPM‑1D.
By Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
The Cross-View Attention Fusion Network (CVAF‑Net) is a dual‑view deep learning model that estimates cardiac output from short photoplethysmography (PPG) segments by combining raw PPG signals with a structured prior‑guided feature sequence map through cross‑view attention. Evaluated on simulated, vasoconstriction, and real‑world activity datasets, CVAF‑Net achieved a mean absolute error of 0.19 L/min on simulated data and as low as 1.20 L/min in real settings, outperforming most benchmarks while reducing computational cost by twelvefold compared to a leading Transformer model. Plausibility checks confirmed physiologically consistent correlations with age, heart rate, and systemic vascular resistance.
By Yaowen Zhang, Bo Cui, Libera Fresiello, Peter H. Veltink, Dirk W. Donker, Ying Wang
arXiv:2607. 27076v1 Announce Type: new Abstract: Continuous cuffless blood pressure (BP) monitoring remains challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditions.
By Kindeep K. Dhatt, Tengyue Wu, Hanbang Hua, Yayun Du
The paper introduces a deep learning-based signal quality assessment model that differentiates clean from noisy ambulatory ECG recordings. It is trained on the Copenhagen Center for Health Technology-Contextualized Arrhythmia Database, the first ambulatory ECG database that includes both physical and patient-reported contextual data. The model maintains stable performance across other datasets such as MIT and PhysioNet/CinC Challenge 2021, and the study demonstrates how the model can be used to investigate complex ECG noise in conjunction with contextual information.
By Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady