The paper presents an anatomy‑aligned surface learning framework for reconstructing patient‑specific 4D myocardial surfaces from sparsely sampled short‑axis cine MRI. By parameterizing epicardial and endocardial surfaces on a shared circumferential‑longitudinal UV domain, the method transforms irregular 3D reconstruction into structured coordinate‑field completion, enabling explicit correspondence across subjects and cardiac phases. Experiments on three public datasets show the approach outperforms mesh‑based and implicit methods, achieving Chamfer distances around 2.6–2.9 mm and preserving ventricular function with small errors in volume and ejection fraction.
By Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis...
arXiv:2606. 13188v1 Announce Type: cross Abstract: Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating.
By Abhishek H S, Akash Ganamukhi, Abhimanyu Suresh, Aditya G Hiremath, Prasad B Honnavalli, Adithya Balasubramanyam
arXiv:2607. 02564v1 Announce Type: cross Abstract: Computational models of the human heart are widely used to study electromechanical and fluid-dynamical cardiac function and to support applications such as in silico clinical trials.
By Francesco Fabbri, Martino Andrea Scarpolini, Paolo Ciancarella, Francesco Tudisco, Roberto Verzicco, Alessandro Ricci, Francesco Viola
arXiv:2608. 19965v1 Announce Type: cross Abstract: Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology.
By Sidi Mohamed Sid'El Moctar, Nicolas Vitry, H\'el\`ene Bouvrais
PPCAR-Net is a neural network that reconstructs 3‑D coronary artery centrelines and radii from a sparse set of X‑ray angiographic views. It predicts a branch‑structured centreline-and‑radius representation directly, avoiding explicit point matching or triangulation. The method refines geometry and radius estimates using projection‑guided refiners and achieves real‑time performance with strong centreline accuracy, especially for the right coronary artery.
By Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo