This paper expands the ImageCAS dataset by adding detailed coronary ostia annotations and centerline graphs rooted at these new landmarks, creating the largest public dataset for ostium localization. The authors employed a human‑in‑the‑loop approach for the first 500 volumes and model‑guided corrections for the remaining 500, then benchmarked six 3D localization models on 58 held‑out scans. SwinUNETR‑V2 and nnResUNet achieved sub‑millimeter median errors with no failures, while the deterministic minimal‑path method produced high‑quality centerlines with a median distance of 0.22 mm to reference points.
By Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia, Andrea Penserini, Christian Brandini, Ender Konukoglu, Marco Marcon, Luca Mainardi, Pietro Cerveri
The paper presents a multi‑task neural network and scalar‑potential solver for reconstructing bilateral coronary artery trees from cardiac CT angiography. It operates on $128^3$ regions of interest, using a 3D pyramid encoder, tubular decoder, and specialized heads for sub‑voxel displacement, ipsilateral territory prediction, and ostium localization. The method achieves sub‑millimetre accuracy on out‑of‑sample and development datasets, outperforming baseline 3D U‑Net models.
By Zeyu Jia, Xin Ming
The paper introduces a novel 3‑D reconstruction framework for bilateral coronary artery trees from cardiac CT angiography, addressing limitations such as voxel quantization, territory ambiguity, and ostium drift. It employs a canonical SO(3) multi‑scale representation, a Riemannian arborescence solver, and a sub‑voxel displacement head, training 327,385 active parameters in a single 30‑epoch AdamW loop. On unseen datasets, the method achieves sub‑millimetre accuracy in centerline distance and ostial localisation, outperforming prior approaches.
By Zeyu Jia, Xin Ming
arXiv:2608. 12274v1 Announce Type: cross Abstract: Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.
By Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind
X-Strata is a neural network that decomposes 2‑D cine X‑ray angiograms into three distinct layers: the full aneurysm sac, vessels in front of the sac, and vessels behind it. By leveraging contrast timing and parallax from two views, the model estimates each layer’s contrast curve, assigns vessels to front or back, and reconstructs the layers in 3‑D. In a study of 220 patients from three centers, X‑Strata outperformed 14 baseline methods, achieving Dice scores of 0.693 (internal) and 0.641 (external) for sac recovery and balanced accuracies of 0.703 and 0.659 for layer ordering.
By Zhihong Wen, Congzhou Chen, Hucheng Li, Xun Han, Jianning Zhang, Yakun Chen, Hao Gao, Hao Zhao, Yudong Ma, Guanqiao Li, Yongping Liang, Shengli Guo
PPCAR-Net is a neural network that reconstructs 3‑D coronary artery centrelines and radii from a sparse set of X‑ray angiographic views. It predicts a branch‑structured centreline-and‑radius representation directly, avoiding explicit point matching or triangulation. The method refines geometry and radius estimates using projection‑guided refiners and achieves real‑time performance with strong centreline accuracy, especially for the right coronary artery.
By Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
arXiv:2606. 23879v1 Announce Type: cross Abstract: Purpose: To evaluate the feasibility and challenges of heart chamber segmentation from non-contrast CT scans using contrastive unpaired image translation and deep learning-based segmentation.
By Jing Wang, Tong Yu, Hao-En Lu, Zixue Zeng, Joseph K. Leader, Xin Meng, Jianbing Zhu, Jiantao Pu
arXiv:2606. 00109v1 Announce Type: cross Abstract: Coronary guidewire endpoint localization is a fundamental capability for computer-assisted PCI, and its importance increases as robot-assisted PCI is progressively adopted to reduce operator radiation exposure.
By Haoyuan Tang, Zhuo Zhang, Jialin Li, Shuai Xiao, Jiachen Yang
arXiv:2606. 13188v1 Announce Type: cross Abstract: Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating.
By Abhishek H S, Akash Ganamukhi, Abhimanyu Suresh, Aditya G Hiremath, Prasad B Honnavalli, Adithya Balasubramanyam
Anchored Slice Propagation with Boundary Transport for 3D CT Segmentation from Three Orthogonal Annotated Slices proposes a method that corrects slice‑to‑slice propagation errors by anchoring predictions at intersecting annotated planes and weighting fusion based on agreement with known labels. The approach also explores transporting boundary geometry via a truncated signed‑distance field and a contour tracker that learns motion cues from supervoxels. Experiments on 2,091 held‑out instances from 403 CT scans show that anchoring improves mean Dice from 0.737 to 0.769, with additional gains from contour tracking and SDF transport on specific organs.
By Tushar Kataria, Md Rakibul Haque, Shireen Y. Elhabian
arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
arXiv:2610.20509v1 Announce Type: cross
Abstract: Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing...
By Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu