arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
The paper presents a coordinate‑free 3‑D neural network with 597,032 parameters for extracting bilateral coronary artery trees from cardiac CT angiography. Using 35 training scans, the authors develop an 8.0 mm corridor solver refined by a learned medial offset, and evaluate the method on 50 ImageCAS and 40 ASOCA scans. Results show superior per‑artery Chamfer distance and centerline F1 scores compared to existing skeletonization and Voronoi‑based methods, achieving fast inference (≈1.66 s/scan) on an NVIDIA L4 GPU.
By Zeyu Jia, Tong Wu, Bo Yao, Xin Ming
X‑LMC is a spatiotemporal deep‑learning framework that automatically scores leptomeningeal collateral (LMC) status from time‑resolved biplane digital subtraction angiography (DSA). It uses a DINOv2 backbone to encode spatial frames, a token‑level cross‑view attention module to fuse orthogonal projections, and a recurrent network to model contrast bolus dynamics. On a multicenter dataset of 134 M1‑segment occlusion patients, X‑LMC achieved a Quadratic Weighted Kappa of 0.398 and a macro‑F1 of 0.711, outperforming static and other spatiotemporal baselines and matching clinical inter‑rater agreement.
X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learnin...
PPCAR-Net is a neural network that reconstructs 3‑D coronary artery centrelines and radii from a sparse set of X‑ray angiographic views. It predicts a branch‑structured centreline-and‑radius representation directly, avoiding explicit point matching or triangulation. The method refines geometry and radius estimates using projection‑guided refiners and achieves real‑time performance with strong centreline accuracy, especially for the right coronary artery.
By Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
XGLASS is a method that transfers expertise from 2D X‑ray vision‑language models to 3D CT volumes by using disease‑conditioned importance maps derived from radiologist gaze on X‑rays. By aligning these gaze priors with coronal CT projections, XGLASS predicts a disease‑specific ordering of axial slices, prioritizing diagnostically relevant slices. The approach achieves a top‑10 hit rate of up to 75.9% on a 240‑slice scan and reduces downstream model calls by 87.5% while improving F1 scores, making it a lightweight preselector for volumetric CT analysis.
By Michael Gl\"ockler, Timo Ropinski
arXiv:2607. 05317v2 Announce Type: replace-cross Abstract: Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates.
By Akshay Gokhale, Mansi Dhamne
arXiv:2607. 05317v1 Announce Type: cross Abstract: Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates.
By Akshay Gokhale (Sardar Patel Institute of Technology, Mumbai), Mansi Dhamne (Sardar Patel Institute of Technology, Mumbai)
DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.
By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner
arXiv:2608. 12274v1 Announce Type: cross Abstract: Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.
By Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind
VeCAS is a two‑stage framework that generates contrast‑free X‑ray angiograms from non‑contrast images. Stage I localizes vascular structures using a discriminative model and cross‑modality latent distillation, while Stage II synthesizes angiographic appearance within those regions with a vessel‑focused inpainting model. Experiments on a lower‑limb vascular intervention dataset show that VeCAS improves vascular structural fidelity and image quality, and robotic guidewire navigation tests demonstrate significant reductions in time to target and operation steps.
By De-Xing Huang, Chen-Yu Wang, Hao Liang, Xiao-Hu Zhou, Mei-Jiang Gui, Tian-Yu Xiang, Qin-Yi Zhang, Chen Wang, Xiao-Liang Xie, Shi-Qi Liu, Ming-Yuan Liu, Zhen-Chang Wang, Zeng-Guang Hou